| Model Number |
N/A |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Code |
Hypersensitivity/Allergic reaction (1907)
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
(b)(4).Product code: phx.Concomitant medical products: catalog#: 113629 comp primary stem 9mm mini lot#: 190250.Catalog#: 010000589 comp rvrs 25mm bsplt ha+adptr lot#: 049210.Catalog#: ti-115310 comp vrsdl glnspr 36mm ti lot#: 211620.Catalog#: 115395 comp rvs cntrl 6.5x25mm st/rst lot#: 526270.Catalog#: 180551 comp lk scr 3.5hex 4.75x20 st lot#: 805130.Catalog#: 180552 comp lk scr 3.5hex 4.75x25 st lot#: 461970.Catalog#: 180553 comp lk scr 3.5hex 4.75x30 st lot#: 980730.Catalog#: 180554 comp lk scr 3.5hex 4.75x35 st lot#: 997650.Catalog#: 110031418 cr prolong 36mm brng std lot#: 64578844.Catalog#:118000 25mm versa-dial taper adaptor lot#: 399130.The device will not be returned for analysis, as the device remains implanted; however, an investigation of the reported event is in progress.Once the investigation has been completed, a follow-up mdr will be submitted.Multiple mdr reports were filed for this event, please see associated reports: 0001825034-2021-00692, 0001825034-2021-00693, 0001825034-2021-00694.
|
| |
|
Event or Problem Description
|
|
It was reported that approximately 8 months post implantation the patient is experiencing itching in and around the shoulder and all over his body.Attempts have been made and additional information on the reported event is unavailable at this time.
|
| |
|
Event or Problem Description
|
|
No further event information is available at the time of this report.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay additional information.No product was returned or pictures provided; visual and dimensional evaluations could not be performed.Review of the device history record(s) identified no deviations or anomalies during manufacturing related to the reported event.The root cause of the reported issue is attributed to the patient's condition - allergy to cobalt.If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
|
| |
|
Event or Problem Description
|
|
No further event information is available at the time of this report.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay additional information.A definitive root cause cannot be determined.Patient noted allergy to cobalt, however, all implanted devices are made of titanium, therefore, it remains unknown what is causing the itching.If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
|
| |
|