• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: NIPRO CORPORATION (ODT) NIPRO CELLENTIA-H; DIALYZER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

NIPRO CORPORATION (ODT) NIPRO CELLENTIA-H; DIALYZER Back to Search Results
Model Number DD+CT21H
Medical Device Problem Code Fluid/Blood Leak (1250)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 02/19/2021
Type of Reportable Event Serious Injury
Event or Problem Description
1 patient / 2 occurrences: where the staff have noticed massive air bubbles in the dialyzer, staff did whatever they could but were not able to clear the bubbles and had to waste the patient's blood.Additional information received 03/02/2021: priming conditions - they prime with a bfr of 100 and flushed the dialyzer with at least a l of saline.Dialysis conditions: bfr 400, dfr: 800, treatment time 4 hrs and no heparin brand/manufacturer name & models of devices used together with dialyzer: gambro machine and lines.How much blood did the patient lost due to changing the dialyzer - 300 ml was any medical actions taken- none as their hgb (as claimed when they rechecked) was stable.Where did the bubbles generate: middle to top portion of the dialyzer.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
NIPRO CELLENTIA-H
Common Device Name
DIALYZER
Manufacturer (Section D)
NIPRO CORPORATION (ODT)
8-7, hanuki-yachi, niida-aza
ohdate-shi, akita 018-5 794
JA  018-5794
MDR Report Key11558902
Report Number1056186-2021-00006
Device Sequence Number16911980
Product Code KDI
UDI-Device Identifier00383790004411
UDI-Public00383790004411
Combination Product (Y/N)N
Initial Reporter StateNE
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Importer
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 03/23/2021
Report Date (Section F) 03/23/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date06/30/2023
Device Model NumberDD+CT21H
Device Catalogue NumberDD+CT21H
Device Lot Number20G27D
Was Device Available for Evaluation? No
Was the Report Sent to FDA? Yes
Distributor Facility Aware Date02/25/2021
Event Location Outpatient Treatment Facility
Date Report to Manufacturer03/25/2021
Initial Date Received by Manufacturer Not provided
Initial Report FDA Received Date03/23/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Date Report Sent to FDA03/23/2021
-
-