Model Number 103-0606-200
Medical Device Problem Code Material Puncture/Hole (1504)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 03/18/2021
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
Medtronic received information regarding an avigo guidewire that punctured the echelon catheter; it was observed the guidewire exited the catheter before reaching the tip.The patient was undergoing an aneurysm embolization procedure to treat an aneurysm in the anterior cerebral artery.Vessel tortuosity was moderate.It was reported that all device were prepared and the catheter flushed per the instructions for use (ifu).During advancement, the avigo guidewire exited the distal end of the echelon catheter lumen proximal to the marker band and it was determined the catheter was ruptured/broken.There was no friction felt during delivery.There was no other damage observed to the echelon catheter.The echelon catheter was replaced by a competitor's device to continue the procedure.There was no harm or injury to the patient.
 
Event or Problem Description
Additional information received reported that the guidewire tip was shaped, and the device was hydrated per the ifu.There was no kink or damage found to the guidewire.It was not determined whether the echelon catheter rupture was due to the puncture by the guidewire.
 
Additional Manufacturer Narrative
Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
0.14 GUIDEWIRES
Common Device Name
WIRE, GUIDE, CATHETER
Manufacturer (Section D)
MICRO THERAPEUTICS, INC. DBA EV3
9775 toledo way
irvine CA 92618
MDR Report Key11591311
Report Number2029214-2021-00367
Device Sequence Number14577077
Product Code DQX
UDI-Device Identifier00847536004764
UDI-Public00847536004764
Combination Product (Y/N)N
Initial Reporter CountryAR
PMA/510(K) Number
K113454
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 04/23/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date12/04/2022
Device Model Number103-0606-200
Device Catalogue Number103-0606-200
Device Lot NumberB001173
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 03/22/2021
Supplement Date Received by Manufacturer04/05/2021
Initial Report FDA Received Date03/30/2021
Supplement Report FDA Received Date04/23/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient Age69 YR
-
-