| Model Number |
495-00-075 |
| Health Effect - Clinical Codes |
Fall (1848); Limb Fracture (4518)
|
| Date of Event |
02/10/2021
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Additional reporting on this event will be provided as a supplemental report to this document if it becomes available.
|
| |
|
Event or Problem Description
|
|
Revision surgery - the patient fell as at the nursing home and fractured their femur.Surgeon plated the femur.He then tried to get the exprt total hip arthroplasty out but was not able to so he had to cut the neck off with a metal cutting burr.
|
| |
|
Event or Problem Description
|
|
Second revision surgery - the patient fell as at the nursing home and fractured their femur.Surgeon plated the femur.He then tried to get the exprt total hip arthroplasty out but was not able to so he had to cut the neck off with a metal cutting burr.
|
| |
|
Additional Manufacturer Narrative
|
|
Manufacturer narrative: the reason for this revision surgery was reported as fractured femur after a fall.The previous revision surgery and the revision surgery detailed in this event occurred 2 days apart.The actual in vivo time for the main part is 2.7 years from the primary surgery.The healthcare professional indicated there was no delay in surgery and another suitable device was available for use.The revision surgery was completed as intended.The device was disposed of at hospital and not made available to djo surgical for examination.A review of the device history record (dhr) shows that the reported component used in the previous surgery, when released for use, met design and manufacturing requirements.There were no non-conforming material report (ncmr) associated with the product that may have contributed to the reported event.The device was verified to have gone through an acceptable sterilization process and was within its expiration date at the time of the previous surgery.Customer complaint history of the reported device showed no present trends or on-going issues that are needing a review.The root cause of this complaint was a revision surgery due to fractured femur after a fall.There were no findings during this evaluation that indicate the reported device was defective.No other information was submitted with the complaint regarding pre-existing conditions of the patient or any activities the patient was involved in that may have contributed to the event.There are multiple factors that may contribute to an event that are outside the control of djo surgical.There are no indications of a product or process issue affecting implant safety or effectiveness.Additional reporting on this event will be provided as a supplemental report to this document as soon as it becomes available.
|
| |
|