| Model Number |
368589 |
| Medical Device Problem Code |
Incorrect, Inadequate or Imprecise Result or Readings (1535)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
03/16/2021
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
A device evaluation is anticipated but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.
|
| |
|
Event or Problem Description
|
|
It was reported the bd vacutainer® k2 edta (k2e) 18 mg blood collection tubes experienced discolored / abnormal additive form.The following information was provided by the initial reporter.The customer stated: it was reported that the plasma looks like jelly."i am reaching out as related to the 10 ml k2edta tube, lot #0167257, exp 06-30-22.We are seeing issues now with approximately 6-7 specimens in which the plasma is described as being like jelly.Have you heard of any issues of this nature from anywhere else.We are wondering if it is this specific lot number alone, as this is the only lot number we currently have on hand for both of our hospital campuses.".
|
| |
|
Event or Problem Description
|
|
It was reported the bd vacutainer® k2 edta (k2e) 18 mg blood collection tubes experienced discolored / abnormal additive form.The following information was provided by the initial reporter.The customer stated: it was reported that the plasma looks like jelly."i am reaching out as related to the 10 ml k2edta tube, lot #0167257, exp 06-30-22.We are seeing issues now with approximately 6-7 specimens in which the plasma is described as being like jelly.Have you heard of any issues of this nature from anywhere else.We are wondering if it is this specific lot number alone, as this is the only lot number we currently have on hand for both of our hospital campuses.".
|
| |
|
Additional Manufacturer Narrative
|
|
The following fields were updated due to additional information: d10: device available for eval yes, d10: returned to manufacturer on: 2021-03-29.H6: investigation summary : bd received 10 contaminated returned samples.Testing cannot be performed on used samples.Therefore, retention samples from bd inventory were evaluated for any additive issues.All testing was within specification.Based on a review of the device history record for the incident lot, all product specifications and requirements for lot release were met.There were no related quality issues during manufacturing of the product.Bd was not able to identify a root cause for the indicated failure mode.H3 other text : see h10.
|
| |
|