MAUDE Adverse Event Report: OMNILIFE SCIENCE, INC. APEX KNEE SYSTEM; PROSTHESIS, KNEE, PATELLOFEMOROTIBIA

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

OMNILIFE SCIENCE, INC. APEX KNEE SYSTEM; PROSTHESIS, KNEE, PATELLOFEMOROTIBIA Back to Search Results
Model Number KP-22211
Health Effect - Clinical Code Unspecified Infection (1930)
Date of Event 03/19/2021
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
The complainant made no indication of any omnilife science device malfunction or deficiency related to the identity, quality, durability, reliability, safety, effectiveness or device performance contributing to the adverse event.Review of the manufacturing documentation and sterilization documentation for the devices in question revealed no deviation from process or non-conformity of product that would have caused or contributed to the adverse event.
 
Event or Problem Description
A complaint was initiated for a patient who underwent a knee revision surgery on (b)(6) 2021.The original surgery date is (b)(6) 2020.The reason for revision is suspected infection.During the revision, the tibial insert and retaining bolt were removed and replaced with new components.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
APEX KNEE SYSTEM
Common Device Name
PROSTHESIS, KNEE, PATELLOFEMOROTIBIA
Manufacturer (Section D)
OMNILIFE SCIENCE, INC.
480 paramount drive
raynham MA 02767
MDR Report Key11683168
Report Number1226188-2021-00050
Device Sequence Number14186912
Product Code JWH
UDI-Device Identifier00841690113508
UDI-Public00841690113508
Combination Product (Y/N)N
Initial Reporter CountryUS
PMA/510(K) Number
K102578
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2020
Device Explanted Year2021
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source company representative
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial
Report Date (Section B) 04/17/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date08/01/2024
Device Model NumberKP-22211
Device Catalogue NumberKP-22211
Device Lot Number34207
Was Device Available for Evaluation? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 03/22/2021
Initial Report FDA Received Date04/17/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Hospitalization; Required Intervention;
Patient Age62 YR
-
-