COOK INC RETRACTA DETACHABLE EMBOLIZATION COIL; KRD DEVICE, EMBOLIZATION, VASCULAR Back to Search Results
Model Number N/A
Medical Device Problem Codes Separation Problem (4043); Difficult or Delayed Separation (4044)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 03/31/2021
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Initial reporter occupation: interventional radiologist.This report includes information known at this time.A follow up report will be submitted should additional relevant information become available.
 
Event or Problem Description
It was reported a male patient required a retracta detachable embolization coil for a left gonadal vein varicocele procedure.During the procedure, it was noted the coil would not deploy and took "far more than 8-10 twists of the wire" to detach from the delivery wire.The physician continued to spin the wire attached to the coil "like 100 times." eventually, the coil detached from the delivery wire and was correctly placed in the patient.As reported, the patient did not experience any adverse effects or require any additional procedures due to this occurrence.
 
Event or Problem Description
No additional information regarding the patient and/or event has been received since the previous medwatch report was sent.
 
Additional Manufacturer Narrative
Correction: h6- annex a.Investigation - evaluation.(b)(6) imaging in the united states informed cook on 02apr2021 of an incident involving a retracta detachable embolization coil [rpn: mwcer-35-14-8] from lot number 13388282.On 31mar2021, during a procedure, the coil was difficult to deploy in the patient.It took about 100 turns for the coil to deploy properly and in the intended area in the patient.The torque device supplied with the product was used during deployment.The junction zone was not damaged.A beacon tip torcon nb advantage angiographic catheter [rpn: hnbr5.0-35-100-p-ns-c2] from lot number 13339044 was used during the procedure.No unintended section of the device remained inside the patient¿s body, the patient did not require additional procedures due to this occurrence, and there have been no adverse effects to the patient as a result.A review of the complaint history, device history record (dhr), instructions for use (ifu), manufacturing instructions (mi), and quality control of the device was conducted during the investigation.The complaint device was not returned; therefore, no physical examinations could be performed.However, a document-based investigation evaluation was performed.A review of the device master record (dmr) concluded that sufficient inspection activities are in place to identify this failure mode prior to distribution.A review of the design history file (dhf) showed that this device is both safe and effective for its intended use.A review of the dhrs for the reported complaint device lot (13388282) and the related delivery wire and coil subassembly lots revealed no recorded non-conformances relevant to the reported failure mode.A database search did not identify any other events associated with the reported device lot.As there are adequate inspection activities established, there is objective evidence that the dhr was fully executed, and there no related non-conformances or additional complaints from the same lot, cook has concluded that the device was manufactured to specification and that there is no evidence suggesting nonconforming product exists either in house or in field.Cook also reviewed product labeling.The product¿s instructions for use [ifu], ¿retractatm detachable embolization coils¿ [t_mwcer_rev5], provides the following information to the user related to the reported failure mode: intended use: ¿the retracta detachable embolization coil is intended for arterial and venous embolization in the peripheral vasculature.¿ warnings: ¿the retracta detachable embolization coil is not recommended for use with polyurethane catheters or catheters with sideports.If a catheter with sideports is used, the embolus may lodge in the sideport or pass inadvertently through it.Use of a polyurethane catheter may also result in lodging of the embolus within the catheter.¿ precautions: ¿prior to introduction of the embolization coil, flush the angiographic catheter with saline.¿ product recommendations: ¿the following catheters are recommended for use with retracta detachable embolization coils: hnb(r)4.0-35, hnb(r)5.0-35, hnb(r)5.0-38, scbr-5.0-38, scbr-4.0-38.¿ instructions for use: ¿6.Under fluoroscopic visualization, slowly advance the delivery wire until the entire length of the coil exits the distal end of the catheter.Ensure that the junction remains positioned just inside the catheter tip.Note: advancing the delivery wire slowly allows the junction to be seen more easily and reduces the risk of damaging it.Note: if significant resistance is encountered during coil advancement, do not continue advancing.Retract the delivery wire slightly, then gently re-advance it.If there is still significant resistance, withdraw the delivery wire from the catheter and try using a new coil with a shorter length." ¿8.If the coil position is correct, use the torque device to turn the delivery wire counterclockwise 8-10 times, until the coil detachment can be either felt or visualized under fluoroscopy.¿ how supplied: ¿upon removal from package, inspect the product to ensure no damage has occurred.¿ based on the information provided, no product returned, and the results of our investigation, a definitive root cause for this event has been traced to a component failure unrelated to a deficiency in manufacturing/device design.It is possible that the failure occurred due to improper handling of the device during deployment, difficult patient anatomy, inadequate product planning (sizing), or preparation for use.It is also possible that the junction was outside of the tip of the catheter during deployment.Without the support and stability of the catheter tip, it is very difficult to release the coil.Keeping the junction just inside the catheter tip during release is stated in the ifu.The appropriate personnel have been notified.Cook will continue to monitor for similar complaints.Per the quality engineering risk assessment no further action is required.This report is required by the fda under 21 cfr part 803 and is based on unconfirmed information submitted by others.Neither the submission of this report nor any statement contained herein is intended to be an admission that any cook device is defective or malfunctioned, that a death or serious injury occurred, nor that any cook device caused, contributed to, or is likely to cause or contribute to a death or serious injury if a malfunction occurred.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
RETRACTA DETACHABLE EMBOLIZATION COIL
Common Device Name
KRD DEVICE, EMBOLIZATION, VASCULAR
Manufacturer (Section D)
COOK INC
750 daniels way
bloomington IN 47404
MDR Report Key11686453
Report Number1820334-2021-01161
Device Sequence Number16915392
Product Code KRD
UDI-Device Identifier10827002341989
UDI-Public(01)10827002341989(17)250912(10)13388282
Combination Product (Y/N)N
Initial Reporter StateNY
Initial Reporter CountryUS
PMA/510(K) Number
K151676
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 07/09/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date09/12/2025
Device Model NumberN/A
Device Catalogue NumberMWCER-35-14-8
Device Lot Number13388282
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 04/02/2021
Supplement Date Received by Manufacturer07/02/2021
Initial Report FDA Received Date04/19/2021
Supplement Report FDA Received Date07/09/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
COOK 100CM C2 BEACON TIP CATHETER
-
-