| Model Number |
N/A |
| Medical Device Problem Code |
Detachment of Device or Device Component (2907)
|
| Health Effect - Clinical Codes |
Damage to Ligament(s) (1952); Pain (1994); Impaired Healing (2378)
|
| Date of Event |
03/12/2019
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
(b)(4).Multiple mdr reports were filed for this event, please see associated report: 0001825034-2021-01217, 0001825034-2021-01219, 0001825034-2021-01220, 0001825034-2021-01221, 0001825034-2021-01222, 0001825034-2021-01223, 0001825034-2021-01224, 0001825034-2021-01225, 0001825034-2021-01226.Medical product: oss reinforced yoke item# 150493; lot# 211420.Oss poly lock pin item# 150478; lot# 348850.Oss non-mod tib plate short 67 item# 150417; lot# 203610.Oss 7cm segmental femoral rt item# 150354; lot# 756200.Oss poly tibial bushing item# 150476; lot# 460720.Oss poly femoral bushings item# 150477; lot# 370100.Oss axle item# 150480; lot# 543370.Oss reinforced yoke item# 150493; lot# 658130.Oss tibial poly bearing 22mm item# 150415; lot# 382120.Oss 3cm ellip diaphyseal seg item# 150461; lot# 150610.Oss cemented im stem 15mmx90mm item# 150363; lot# 810360.Customer has indicated that the product will not be returned to zimmer biomet for investigation.The investigation is in process.Once the investigation has been completed, a follow-up mdr will be submitted.
|
| |
|
Event or Problem Description
|
|
It was reported that a patient was revised approximately two months¿ post implantation due to wound healing problems that disengaged his hinged femur from his right tibial component.This was a result of having had a distal femoral replacement with absence of collateral ligaments causing the femur to disengage from the tibia when the knee became flexed.Attempts to obtain additional information have been made; however, no more information is available.
|
| |
|
Event or Problem Description
|
|
No further event information available at the time of this report.
|
| |
|
Additional Manufacturer Narrative
|
|
No product was returned or pictures provided; therefore, visual and dimensional evaluations could not be performed.Medical records were not provided.Device history record (dhr) was reviewed for deviations and/ or anomalies with no related deviations / anomalies identified.A definitive root cause cannot be determined.If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
|
| |
|