| Catalog Number |
0057570 |
| Medical Device Problem Codes |
Fluid/Blood Leak (1250); Detachment of Device or Device Component (2907)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
04/06/2021
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
At this time, no conclusion can be made.While the sample evaluation is anticipated, it has not get begun.To date, this is the only reported complaint for this manufacturing lot.When the investigation has been completed, a supplemental mdr will be submitted.
|
| |
|
Event or Problem Description
|
|
As reported, during the setup of a procedure on (b)(6) 2021, the bard/davol simpulse plus irrigator leaked saline because the connector near the saline solution inflow was poorly connected.In addition, when pressure was applied, the connection suddenly came off.Another device was used to complete the procedure.There was no reported patient injury.
|
| |
|
Additional Manufacturer Narrative
|
|
At this time, no conclusion can be made.While the sample evaluation is anticipated, it has not get begun.To date, this is the only reported complaint for this manufacturing lot.Addendum: this is an addendum to the initial mdr submitted.This supplemental mdr is submitted to document the results of sample evaluation.The subject device was returned for evaluation.Evaluation of the sample finds that the pump body is separated in half at the weld which would result in a fluid leak as reported.It is likely the pump housing was misaligned during the manufacturing process resulting in the separation of the housing halves during use.Review of manufacturing records indicate product was manufactured to specification.To date this is the only reported complaint for this manufacturing lot of (b)(4) units released for distribution in december 2019.Based on the sample evaluation and investigation performed, the root cause is determined to be manufacturing related.Note: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant/reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text: sample evaluated.
|
| |
|
Event or Problem Description
|
|
As reported, during the setup of a procedure on (b)(6) 2021, the bard/davol simpulse plus irrigator leaked saline because the connector near the saline solution inflow was poorly connected.In addition, when pressure was applied, the connection suddenly came off.Another device was used to complete the procedure.There was no reported patient injury.
|
| |
|