Model Number 68LP-400
Medical Device Problem Code Fluid/Blood Leak (1250)
Health Effect - Clinical Code Failure of Implant (1924)
Date of Event 03/31/2021
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Further information from the reporter regarding event, product, or patient details has been requested.No additional information is available at this time.A review of the device history record has been completed.No deviations or non-conformances noted.Reason for reoperation: deflation.
 
Event or Problem Description
Healthcare professional reported right side deflation.The device remains implanted.
 
Additional Manufacturer Narrative
Device evaluation: the device related to the reported event of deflation was received on july 06, 2021 with lot number: 3216583.Visual analysis of the returned device identified: flat creases and no openings were found in the device.A leak test was performed which identified no leakage.Fill inspection was performed and identified no blockage in the valve.Based on the device analysis the final assessment is: no observations found related with the complaint reported by the physician.Additional, changed, and/or corrected data.
 
Event or Problem Description
Device has been explanted and replaced.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
STYLE 68 SALINE FILLED BREAST IMPLANT
Common Device Name
PROSTHESIS, BREAST, INFLATABLE, INTERNAL, SALINE
Manufacturer (Section D)
ALLERGAN (COSTA RICA)
900 parkway global park
zona franca
MDR Report Key11748407
Report Number9617229-2021-06764
Device Sequence Number4066065
Product Code FWM
UDI-Device Identifier10888628000612
UDI-Public10888628000612
Combination Product (Y/N)N
Initial Reporter StateFL
Initial Reporter CountryUS
PMA/510(K) Number
P990074
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2018
Device Explanted Year2021
Reporter Type Manufacturer
Report Source health professional
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 08/02/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date05/08/2022
Device Model Number68LP-400
Device Catalogue Number68LP-400
Device Lot Number3216583
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer07/06/2021
Initial Date Received by Manufacturer 04/02/2021
Supplement Date Received by Manufacturer07/06/2021
Initial Report FDA Received Date04/29/2021
Supplement Report FDA Received Date08/02/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age54 YR
-
-