Model Number PED-400-20
Medical Device Problem Codes Unintended Movement (3026); Physical Resistance/Sticking (4012)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 04/22/2021
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
Medtronic received a report that the pipeline moved during deployment.The patient was undergoing treatment for an unruptured, fusiform aneurysm located in the right posterior communicating artery.The max diameter was 6mm.The patient's vessel tortuosity was moderate.The landing zone was 2.2mm distal and 3.9mm proximal. dual antiplatelet treatment was administered, and the pru level was 83.It was reported that the pipeline slid back short of intended landing zone.The physician attempted to recapture the device but could not.The pipeline was removed and replaced.There had not been any friction or difficulty during delivery or positioning, and multiple pipeline devices were not being used at the time.The corking technique was used to remove the pipeline, but no additional devices were used to remove the it.It was noted that the pipeline had jumped during deployment.The pipeline had been placed at least 3mm past the aneurysm neck on each side, and no side branches were covered by the device.The tip of the catheter had been moved during deployment. angiographic results post procedure showed stasis in the aneurysm and a patent parent vessel. the patient did not experience any injury or complications.The devices were prepared according to the instructions for use (ifu).Ancillary devices include a ballast 80cm sheath, phenom plus guide catheter, phenom 27 microcatheter, and synchro 2 standard guidewire.
 
Additional Manufacturer Narrative
Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
Additional information received reported the catheter was flushed continuously during the procedure.There was no damage observed to the pipeline pushwire.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PIPELINE FLEX
Common Device Name
INTRACRANIAL ANEURYSM FLOW DIVERTER
Manufacturer (Section D)
MICRO THERAPEUTICS, INC. DBA EV3
9775 toledo way
irvine CA 92618
MDR Report Key11766733
Report Number2029214-2021-00523
Device Sequence Number11693598
Product Code OUT
UDI-Device Identifier00847536015937
UDI-Public00847536015937
Combination Product (Y/N)N
Initial Reporter StateFL
Initial Reporter CountryUS
PMA/510(K) Number
P100018.S011
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 05/25/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date07/09/2023
Device Model NumberPED-400-20
Device Catalogue NumberPED-400-20
Device Lot NumberB051701
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 04/22/2021
Supplement Date Received by Manufacturer05/04/2021
Initial Report FDA Received Date05/03/2021
Supplement Report FDA Received Date05/25/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient Age64 YR
Patient Weight72
-
-