Catalog Number SAVI-10/B
Medical Device Problem Codes Fracture (1260); Material Separation (1562)
Health Effect - Clinical Code Foreign Body In Patient (2687)
Date of Event 04/16/2021
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
The suspect device was not returned.A complete investigation could not be performed.A lot number was reported, and a review of the manufacturing history record is in progress.Should the device be returned at a later date, the investigation will be re-opened.
 
Event or Problem Description
The account alleges that during an accelerated partial breast irradiation (apbi) procedure on (b)(6) 2021, the brachytherapy device was implanted and deployed to deliver radiation directly to the lumpectomy site for the patient.The catheters expand to fit the size and shape of the tumor cavity.Catheter #1 on the brachytherapy bundle device broke 6cm from the distal end.The account alleges that there was not enough catheter extending beyond the handle to attach the transfer guide tube.A new treatment plan was initiated without the #1 catheter and the 9th fraction was completed.The 10th and last fraction was completed on the afternoon of (b)(6) 2021.The account alleges that during an attempt to remove the brachytherapy bundle device, the expansion tool detached from the distal end.The physician was unable to collapse the device for removal.The patient was sent to a surgeon's office for device removal.The incision site was enlarged, and the brachytherapy bundle device was successfully removed.A penrose drain was placed, and the incision site was closed with proline sutures.The patient was sent home with no additional consequences to report.
 
Additional Manufacturer Narrative
The suspect device was not returned for evaluation however photographs of the suspect unit were provided.The complaint was confirmed based on the photographs provided.The root cause could not be determined.The device history record was reviewed, and no exception documents were found.A search of the complaint database was performed and no similar complaints with this lot number were identified.Should the device be returned at a later date, the investigation will be re-opened.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SAVI®.APPLICATOR TRAY
Common Device Name
REMOTE CONTROLLED RADIONUCLIDE APPLICATOR SYSTEM.
MDR Report Key11784268
Report Number1721504-2021-00028
Device Sequence Number3215206
Product Code JAQ
UDI-Device Identifier00884450434291
UDI-Public884450434291
Combination Product (Y/N)N
Initial Reporter StateNC
Initial Reporter CountryUS
PMA/510(K) Number
K081677
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 04/20/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date11/30/2021
Device Catalogue NumberSAVI-10/B
Device Lot NumberH1689864
Initial Date Received by Manufacturer 04/20/2021
Supplement Date Received by Manufacturer06/21/2021
Initial Report FDA Received Date05/06/2021
Supplement Report FDA Received Date06/30/2021
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured01/28/2020
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Hospitalization; Required Intervention;
-
-