Model Number 1294-54-100
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581)
Date of Event 05/04/2021
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
(b)(4).If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event or Problem Description
The patient was revised to address infection.Convert to antibiotic spacer.A depuy cement was used.No surgical delay.Doi: (b)(6) 2021, dor: (b)(6) 2021, left knee.
 
Additional Manufacturer Narrative
Product complaint # (b)(4).Investigation summary : no device associated with this report was received for examination.Depuy synthes considers the investigation closed at this time.Should additional information be received, the information will be reviewed and the investigation may be re-opened as necessary.Device history lot : the product investigation found no evidence suspecting an error in the manufacturing or material that would be a contributing factor in the reported allegation(s).A manufacturing records evaluation (mre) was not performed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MBT TRAY SLEEVE POR M/L 37MM
Common Device Name
MBT TIBIAL TRAY : KNEE TIBIAL TRAY ACCESSORY
Manufacturer (Section D)
DEPUY ORTHOPAEDICS INC US
700 orthopaedic drive
warsaw IN 46581 0988
MDR Report Key11820238
Report Number1818910-2021-10219
Device Sequence Number3746841
Product Code NJL
UDI-Device Identifier10603295026419
UDI-Public10603295026419
Combination Product (Y/N)N
Initial Reporter StateTX
Initial Reporter CountryUS
PMA/510(K) Number
P830055
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2021
Device Explanted Year2021
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 05/04/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model Number1294-54-100
Device Catalogue Number129454100
Device Lot NumberJ98P66
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 05/04/2021
Supplement Date Received by Manufacturer06/29/2021
Initial Report FDA Received Date05/13/2021
Supplement Report FDA Received Date06/30/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
MBT REVISION CEM TIB TRAY SZ 3; MBT TRAY SLEEVE POR M/L 37MM; PFC SIGMA FEM POST AUG SZ4 4MM; PFC SIGMA FEM POST AUG SZ4 8MM; PFC*SIGMA TC3 FEM LEFT SZ4; PFC*SIGMA/RD/DOME PAT 3PEG,38; SIG FEM ADAP +2/-2 OFFSET BOLT; SIGMA FEM ADAPTER 5 DEGREE; SMARTSET MV 40G - EO; TC3 RP TIBIAL INSERT S3,10.0; UNIVERSAL FEM SLV FUL POR 31MM; UNIVERSAL STEM 75X16MM FLUTED; UNIVERSAL STEM 75X16MM FLUTED; MBT REVISION CEM TIB TRAY SZ 3; MBT TRAY SLEEVE POR M/L 37MM; PFC SIGMA FEM POST AUG SZ4 4MM; PFC SIGMA FEM POST AUG SZ4 8MM; PFC*SIGMA TC3 FEM LEFT SZ4; PFC*SIGMA/RD/DOME PAT 3PEG,38; SIG FEM ADAP +2/-2 OFFSET BOLT; SIGMA FEM ADAPTER 5 DEGREE; SMARTSET MV 40G - EO; TC3 RP TIBIAL INSERT S3,10.0; UNIVERSAL FEM SLV FUL POR 31MM; UNIVERSAL STEM 75X16MM FLUTED; UNIVERSAL STEM 75X16MM FLUTED
Outcome Attributed to Adverse Event Required Intervention;
Patient Age52 YR
-
-