Model Number 6260-5-226
Medical Device Problem Code Device Difficult to Setup or Prepare (1487)
Health Effect - Clinical Code Insufficient Information (4580)
Date of Event 04/19/2021
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Review of the device history records indicate devices were manufactured and accepted into final stock with no relevant reported discrepancies.There have been no other similar events for the lot referenced.It was noted that the device is not available for evaluation.Should additional information become available, it will be provided in a supplemental report upon completion of the investigation.
 
Event or Problem Description
After inserting the stem into the femur and firmly driving the inner head reported this time, surgeon inserted a bipolar cup and tried to reduce it.Then, the inner head was disengaged from the stem rolled down to the outside.So the head became dirty.The bipolar cup and inner head were raised one size.
 
Additional Manufacturer Narrative
Reported event: an event regarding seating/locking issues involving a metal head was reported.The event was not confirmed.Method & results: -product evaluation and results: visual inspection of the returned device noted the following: visual inspection of the returned device identified nothing remarkable to report.Dimensional inspection: the device is dimensionally within specification as per inspection completed by manufacturing cell representative.Inspection report attached.Functional inspection: functional inspection of the returned device noted the following: material analysis: not performed as this event does not relate to material integrity.-clinician review: no medical records were received for review with a clinical consultant.-product history review: review of the device history records indicate devices were manufactured and accepted into final stock with no relevant reported discrepancies.-complaint history review: there have been no other similar events for the lot referenced.Conclusions: the exact cause of the event could not be determined because insufficient information was provided.Further information such as pathology reports, pre- and post-operative x-rays and the primary operative report as well as patient history and follow-up notes are needed to complete the investigation for determining root cause.No further investigation for this event is possible at this time.If additional information becomes available to indicate further evaluation is warranted, this record will be reopened.
 
Event or Problem Description
After inserting the stem into the femur and firmly driving the inner head reported this time, surgeon inserted a bipolar cup and tried to reduce it.Then, the inner head was disengaged from the stem rolled down to the outside.So the head became dirty.The bipolar cup and inner head were raised one size.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
26MM +4 V40 TAPER VIT HEAD
Common Device Name
PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, CEMENTED
Manufacturer (Section D)
STRYKER ORTHOPAEDICS-MAHWAH
325 corporate drive
mahwah NJ 07430
MDR Report Key11832625
Report Number0002249697-2021-00864
Device Sequence Number17074883
Product Code JDI
UDI-Device Identifier07613327012880
UDI-Public07613327012880
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K173499
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2021
Reporter Type Manufacturer
Report Source distributor,other
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 09/28/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date01/31/2025
Device Model Number6260-5-226
Device Catalogue Number6260-5-226
Device Lot Number77226603
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/01/2021
Initial Date Received by Manufacturer 04/20/2021
Supplement Date Received by Manufacturer09/03/2021
Initial Report FDA Received Date05/17/2021
Supplement Report FDA Received Date09/28/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient Age59 YR
-
-