Model Number 280.285S
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581)
Date of Event 09/21/2018
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Additional product code: ktt.Complainant part is not expected to be returned for manufacturer review/investigation.(b)(4).Without a lot number the device history records review could not be completed.Product was not returned.Based on the information available, it has been determined that no corrective and/or preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event or Problem Description
It was reported that on (b)(6) 2018 , the patient had wi fracture of her intertrochanteric hip area and underwent an open reduction internal fixation surgery.Procedure was completed successfully.On or about (b)(6) 2020, two years following her hip procedure, she was returning home and inside of her garage her hip gave out.Patient then saw her surgeon to describe the issue to him and x-rays were completed which revealed that the screws had all broken and the plate connecting the hip had pulled away from her femur with fracturing.The patient immediately went into another surgery to rectify the situation.It was detailed that all the screws that were inserted had failed over the two year period since her initial surgery.Patient underwent revision surgery for the removal of hardware and the femoral fracture was re-plated utilizing screws from another manufacturer.This report is for one (1) dhs/dcs one-step lag screw 12.7mm thread/85mm-sterile.This is report 1 of 6 for complaint (b)(4).
 
Additional Manufacturer Narrative
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.H6 - codes updated to imdrf codes.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Additional Manufacturer Narrative
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event or Problem Description
The patient was revised on (b)(6) 2020 to remove the broken screw heads.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
DHS/DCS ONE-STEP LAG SCR 12.7 THRD/85-S
Common Device Name
DEVICE, FIXATION, PROXIMAL FEMORAL, IMPLANT
Manufacturer (Section D)
WRIGHTS LANE SYNTHES USA PRODUCTS LLC
1302 wrights lane east
west chester PA 19380
MDR Report Key11838246
Report Number2939274-2021-02391
Device Sequence Number4491693
Product Code JDO
UDI-Device Identifier10886982175144
UDI-Public(01)10886982175144
Combination Product (Y/N)N
Initial Reporter StateWI
Initial Reporter CountryUS
PMA/510(K) Number
K964259
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2018
Device Explanted Year2020
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source company representative,other
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup,Followup,Followup
Report Date (Section B) 04/20/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device No Information
Device Model Number280.285S
Device Catalogue Number280.285S
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 04/20/2021
Supplement Date Received by Manufacturer04/20/2021
06/09/2021
08/25/2021
Initial Report FDA Received Date05/17/2021
Supplement Report FDA Received Date05/18/2021
06/09/2021
09/22/2021
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
CORTSCR Ø4.5 SELF-TAP L38 SST; CORTSCR Ø4.5 SELF-TAP L38 SST; CORTSCR Ø4.5 SELF-TAP L38 SST; UNK - PLATES; UNK - SCREWS: TRAUMA
Outcome Attributed to Adverse Event Required Intervention;
Patient Age57 YR
-
-