Model Number 48289999
Medical Device Problem Codes Use of Device Problem (1670); Migration (4003)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 04/27/2021
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Device remains in patient.
 
Event or Problem Description
It was reported that during the procedure, a mantis redux blocker was inadvertently left in the patient.An xray was performed and an additional set screw was observed.Revision is scheduled in the future.
 
Additional Manufacturer Narrative
These fields have been corrected following receipt of additional communication from the field: b1, b2, b5, h1.The device remains implanted and is unavailable for evaluation.Device history record review could not be performed as a valid lot code was not provided and could not be obtained.A review of complaint history associated with the subject catalog number was performed and no adverse trends were observed.Additional correspondence with the field representative: "the doctor misunderstood that they probably did not deploy a blocker in screw head and they inserted a new blocker on the top of the blocker that had already been in place." from mantis surgical technique: improper selection, placement, positioning and fixation of these devices may result in unusual stress conditions reducing the service life of the implant.The most likely root cause of the reported event is user error.
 
Event or Problem Description
It was reported that during the procedure, a mantis redux blocker was inadvertently left in the patient.An x-ray was performed and an additional set screw was observed.Revision surgery is not planned.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MANTIS REDUX BLOCKER
Common Device Name
THORACOLUMBOSACRAL PEDICLE SCREW SYSTEM
Manufacturer (Section D)
STRYKER SPINE-US
2 pearl court
allendale NJ 07401
MDR Report Key11872852
Report Number0009617544-2021-00088
Device Sequence Number19044415
Product Code NKB
UDI-Device Identifier04546540671431
UDI-Public04546540671431
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K092631
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2021
Reporter Type Manufacturer
Report Source distributor
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 09/24/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number48289999
Device Catalogue Number48289999
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 04/28/2021
Supplement Date Received by Manufacturer08/27/2021
Initial Report FDA Received Date05/24/2021
Supplement Report FDA Received Date09/24/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age76 YR
Patient Weight80
-
-