ZIMMER ORTHOPAEDIC MFG. LTD. CR-FLEX PCT FEM F-R MINUS; PROSTHESIS, KNEE Back to Search Results
Model Number N/A
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Damage to Ligament(s) (1952)
Date of Event 05/14/2021
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
(b)(4).Multiple mdr reports were filed for this event, please see associated reports: 3007963827-2021-00129, 0001822565-2021-01619, 0002648920-2021-00151, and 0002648920-2021-00152.Concomitant medical products: articular surface use with plate 5,6 size green/c-h 10 mm height catalog#: 00595204010 lot#: 63564755.Stemmed tibial component precoat size 5 catalog#: 00598004701 lot#: 63565275.All poly patella standard size 32 mm diameter 8.5 mm thickness cemented catalog#: 00597206532 lot#: 63534851.Foreign country: (b)(6).Customer has indicated that the product will not be returned to zimmer biomet for investigation, as its current location is unknown.The investigation is in process.Once the investigation has been completed, a follow-up mdr will be submitted.
 
Event or Problem Description
It was reported that patient underwent a right knee revision approximately four years post-implantation due to a deficient posterior cruciate ligament.Attempts to obtain additional information have been made; however, no more is available.
 
Event or Problem Description
No further event information available at the time of this report.
 
Additional Manufacturer Narrative
This follow-up report is being submitted to relay additional information.Reported event was unable to be confirmed due to limited information received from the customer.Device history record was reviewed and no discrepancies were found.Review of complaint history found no additional related issues for these items and the reported part and lot combinations.Root cause was unable to be determined as the necessary information to adequately investigate the reported event was not provided.If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CR-FLEX PCT FEM F-R MINUS
Common Device Name
PROSTHESIS, KNEE
Manufacturer (Section D)
ZIMMER ORTHOPAEDIC MFG. LTD.
building no 2 east park
shannon industrial estate
shannon, county clare
EI 
MDR Report Key11976710
Report Number3007963827-2021-00129
Device Sequence Number1153380
Product Code JWH
UDI-Device Identifier00889024207042
UDI-Public(01)00889024207042(17)261130(10)63525591
Combination Product (Y/N)N
Initial Reporter CountryAS
PMA/510(K) Number
K023211
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2017
Device Explanted Year2021
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 10/12/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model NumberN/A
Device Catalogue Number00595001606
Device Lot Number63525591
Was Device Available for Evaluation? No
Was the Report Sent to FDA? No
Initial Date Received by Manufacturer 05/14/2021
Supplement Date Received by Manufacturer10/05/2021
Initial Report FDA Received Date06/10/2021
Supplement Report FDA Received Date10/12/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
If action reported to FDA under 21 USC 360i(g), list
FDA-assigned Recall Number or include a statement
N/A
Patient Sequence Number1
Outcome Attributed to Adverse Event Hospitalization; Required Intervention;
-
-