C.R. BARD, INC. (COVINGTON) -1018233 ALIGN TO URETHRAL SUPPORT SYSTEM - HOOK; ALIGN® TO URETHRAL SUPPORT SYSTEM - HOOK
|
Back to Search Results |
|
| Model Number |
BRD400HK |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Abdominal Pain (1685); Autoimmune Disorder (1732); Erosion (1750); Diarrhea (1811); Hemorrhage/Blood Loss/Bleeding (1888); Pain (1994); Urinary Tract Infection (2120); Urinary Frequency / Polyuria (2275); Arthralgia (2355); Prolapse (2475); Hematuria (2558); Constipation (3274); Dyspareunia (4505); Urinary Incontinence (4572); Swelling/ Edema (4577)
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
The reported event could not be confirmed.No sample was returned for evaluation.Based on the investigation findings, current manufacturing controls are considered adequate as to detect and segregate any non-conforming unit.Event described could not be confirmed as a manufacturing related issue.Precautions: the usual precautions associated with urological procedures should be followed: accepted surgical practice and precautions must be followed for the management of contaminated or infected wound sites, when the align¿ to urethral support system is used.Postoperative bleeding may occur in some patients and must be controlled prior to patient release.The implant procedure requires diligent attention to anatomical structure and care to avoid puncture of large vessels, nerves, bladder, and any viscera, during introducer needle passage.Proper placement of the mesh sling implant at mid-urethra requires that it lies flat with minimal or no tension under the urethra.The align¿ to urethral support system is intended as a single-use, disposable device.Do not resterilize any portion of the align¿ to urethral support system.Patients should be advised that pregnancy following a mesh sling implant procedure may negatively affect the success of the previous implant procedure and incontinence may reoccur.The safety and effectiveness of the align¿ to urethral support system implant procedure has not been established for the treatment of stress urinary incontinence in males and children under the age of 18.Cystoscopy can be considered at the physician¿s discretion.Do not use the align¿ to urethral support system if the packaging is opened or damaged.After use, this product may be a potential biohazard.Handle and dispose of in accordance with accepted medical practice and applicable local, state and federal laws and regulations.Adverse events: complications associated with the proper implantation of the align¿ to urethral support system may include, but are not limited to: postoperative hematoma, which may occur following the implant procedure.Temporary urinary retention, bladder outlet obstruction, and voiding difficulties associated with over correction/too much tension placed on the mesh sling implant.Perforations or lacerations of vessels, nerves, bladder or any viscera, which may occur during introducer needle passage.Transitory irritation at the operative wound site, which may elicit a foreign body response that leads to inflammation, infection, or erosion of the implant.(b)(4).
|
| |
|
Event or Problem Description
|
|
The patient's attorney alleged a deficiency against the device.Additional information has been requested, but not yet received.Per additional information received on 04jun2021, the patient experienced vaginal mesh erosion, pain, dyspareunia, urge incontinence, urinary frequency, nocturia, bleeding, cystocele, enterocele, rectocele, recurrent vaginal pain, urinary incontinence, uterine prolapse, vaginal atrophy, incomplete emptying, frequent urinary tract infections, hematuria, kidney stones, kidney problems, vaginal pressure, constipation, diarrhea, autoimmune disease, leg swelling, arthralgias and required additional surgical and non-surgical interventions.
|
| |
|