| Model Number |
N/A |
| Medical Device Problem Codes |
Crack (1135); Fluid/Blood Leak (1250)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
05/03/2021
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
The manufacturer has received the sample and will evaluate.Results are expected soon.A lot history review (lhr) of reey3313 showed no other similar product complaint(s) from this lot number.
|
| |
|
Event or Problem Description
|
|
It was reported the item has come in damaged.No other information provided.Additional information received 05/26/2021 "port a cath tubing was leaking at a random spot in the tubing.Needed to deaccess port and reaccess port with new tubing.".
|
| |
|
Event or Problem Description
|
|
It was reported the item has come in damaged.No other information provided.Additional information received 05/26/2021 "port a cath tubing was leaking at a random spot in the tubing.Needed to deaccess port and reaccess port with new tubing.".
|
| |
|
Additional Manufacturer Narrative
|
|
H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.The following were reviewed as part of this investigation: patient severity, trend analysis, applicable previous investigation(s), sample (if available), and applicable fmea documents.Based on a review of this information, the following was concluded: the complaint of a cracked y-site luer hub was confirmed and the cause was supplier-related.The product returned for evaluation was one 20ga x 1¿ powerloc safety infusion set with y-site.Usage residues were observed throughout the sample and needleless injection caps were attached to both luer adapters.A crack was observed in the y-site, opposite the molding gate.The crack appeared to originate at the luer orifice and propagated along a molding weld line in the material.Microscopic inspection of the y-site confirmed that the crack propagated along a weld line feature in the material.The crack exhibited a granular fracture surface.Abundant superficial stress fracturing was observed throughout the region of the y-site near the orifice.The crack occurred along a molding feature in the y-site material.The abundant stress fracturing was also indicative of material embrittlement, likely caused by manufacturing conditions.The device is a supplied component and the supplier has been notified of this event.
|
| |
|
Search Alerts/Recalls
|