Model Number 71453212
Medical Device Problem Code Incomplete or Inadequate Connection (4037)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 05/26/2021
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that, during tka surgery, a legion ps high flex xlpe size 3-4 11mm did not match with the baseplate.Surgery was completed with a back-up device of the same size.It is unknown if this caused any delay in the surgery.Patient was not injured as consequence of this problem.
 
Additional Manufacturer Narrative
G3, h2,h3 and h6: the associated device, used in treatment, was returned and evaluated.A visual inspection of the returned insert confirms minor damage, more than likely from attempted insertion.The legion ps high flex xlpe is damaged around the base and lock, therefore making it difficult to mate with the baseplate.A dimensional inspection was attempted but the device was too damaged from the attempted insertion to obtain accurate measurements.A review of complaint history did not reveal additional complaints for the listed batch.A review of the manufacturing records did not reveal a manufacturing abnormality that could have caused or contributed to the reported incident.At this time, we do not have reason to suspect that the product failed to meet any product specifications at the time of manufacture.Some potential probable causes for this event could include a fit/ sizing issue or poor insertion technique.Based on this investigation, the need for corrective action is not indicated.Should additional information be received, the complaint will be reopened.No further investigation is warranted for this complaint; however, we will continue to monitor for future complaints and investigate as necessary.We consider this investigation closed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
LGN PS HIGH FLEX XLPE SZ 3-4 11MM
Common Device Name
PROSTH, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONST, CEMENTED, POLY/METAL/POLY
Manufacturer (Section D)
SMITH & NEPHEW, INC.
1450 brooks rd.
memphis TN 38116
MDR Report Key12038857
Report Number1020279-2021-05285
Device Sequence Number19748431
Product Code JWH
UDI-Device Identifier00885556034170
UDI-Public00885556034170
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K071071
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 08/09/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number71453212
Device Catalogue Number71453212
Device Lot Number20CT35471
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer06/28/2021
Initial Date Received by Manufacturer 06/03/2021
Supplement Date Received by Manufacturer08/09/2021
Initial Report FDA Received Date06/22/2021
Supplement Report FDA Received Date08/09/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient Age62 YR
-
-