SMITH & NEPHEW, INC. SPEC EF 12/14 LS 225MM S; PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, CEMENTED Back to Search Results
Model Number 71312237
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Unspecified Infection (1930)
Date of Event 06/08/2021
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that, after a hip replacement surgery had been performed on (b)(6) 2020, the patient experienced an unspecified infection.This adverse event was solved by performing a two revision surgeries, the latest on (b)(6) 2021.Current health status of patient in unknown.
 
Additional Manufacturer Narrative
H3, h6: the device, used in treatment, was not returned for evaluation and the reported event could not be confirmed.The clinical / medical investigation concluded that, per complaint details, the second-stage revision was performed approximately 6-months post first-stage revision due to an unspecified infection.Per correspondence, the surgeon did not fault the devices as they "were intended to be removed when implanted¿.It was communicated that an attempt was being made to recover the stem, but it was ¿likely thrown out¿ and no further information was available for inclusion in the medical investigation.Reportedly, the clinical root cause of the 2-stage revision was an infection; however, the root cause of the infection could not be assessed.The patient impact beyond the reported infection and subsequent 2-stage revision could not be determined.No further medical assessment could be rendered at this time.Should clinically relevant documentation become available in the future, this case may be re-opened/re-assessed.A review of complaint history did not reveal additional complaints for the listed device.A review of the risk management file and instructions for use documents revealed this failure mode was previously identified.Possible causes could include but not limited to contamination, patient reaction, and post-operative healing issue.Based on this investigation, the need for corrective action is not indicated.Should the device or additional information be received, the complaint will be reopened.No further investigation is warranted for this complaint; however, we will continue to monitor for future complaints and investigate as necessary.We consider this investigation closed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SPEC EF 12/14 LS 225MM S
Common Device Name
PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, CEMENTED
Manufacturer (Section D)
SMITH & NEPHEW, INC.
1450 brooks rd.
memphis TN 38116
MDR Report Key12046422
Report Number1020279-2021-05353
Device Sequence Number3348007
Product Code JDI
UDI-Device Identifier03596010386427
UDI-Public03596010386427
Combination Product (Y/N)N
Initial Reporter CountryAS
PMA/510(K) Number
K970351
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2020
Device Explanted Year2021
Reporter Type Manufacturer
Report Source foreign,health professional
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 07/28/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number71312237
Device Catalogue Number71312237
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 06/08/2021
Supplement Date Received by Manufacturer07/28/2021
Initial Report FDA Received Date06/22/2021
Supplement Report FDA Received Date07/28/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Hospitalization; Other; Required Intervention;
-
-