Model Number MICL12.6
Medical Device Problem Codes Misfocusing (1401); Off-Label Use (1494); Optical Problem (3001)
Health Effect - Clinical Codes Headache (1880); Blurred Vision (2137); Visual Disturbances (2140); Halo (2227)
Date of Event 02/23/2021
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Enlarge pis.This lens model is contraindicated for patients with age less than that of 21 years.(b)(4).
 
Event or Problem Description
The reporter indicated the surgeon implanted a 12.6mm micl12.6 implantable collamer lens, -10.00 diopter, in the patients left eye (os) on (b)(6) 2021.The lens was explanted on (b)(6) 2021 due to transient loss of best corrected visual acuity (bcva), glare/halos, headache and blurred vision.The pis were enlarged by yag.The lens was exchanged for a shorter lens and the problem was resolved.The icl is in a good position and no more headaches.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
IMPLANTABLE COLLAMER LENS (ICL)
Common Device Name
PHAKIC INTRAOCULAR LENS
Manufacturer (Section D)
STAAR SURGICAL COMPANY
1911 walker avenue
monrovia CA 91016
MDR Report Key12052969
Report Number2023826-2021-02042
Device Sequence Number11852075
Product Code MTA
UDI-Device Identifier00841542103022
UDI-Public00841542103022
Combination Product (Y/N)N
Initial Reporter StateFL
Initial Reporter CountryUS
PMA/510(K) Number
P030016
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2021
Device Explanted Year2021
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source health professional
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 05/24/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date12/31/2021
Device Model NumberMICL12.6
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 05/24/2021
Initial Report FDA Received Date06/23/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age20 YR
-
-