• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: CONCORD MANUFACTURING 2008T HEMODIALYSIS SYSTEM WITHOUT CDX; DIALYZER, HIGH PERMEABILITY WITH OR WITHOUT SEALED DIALYSATE SYSTEM

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

CONCORD MANUFACTURING 2008T HEMODIALYSIS SYSTEM WITHOUT CDX; DIALYZER, HIGH PERMEABILITY WITH OR WITHOUT SEALED DIALYSATE SYSTEM Back to Search Results
Model Number 190858
Medical Device Problem Code Thermal Decomposition of Device (1071)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 06/11/2021
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Plant investigation: the plant investigation is in process.A supplemental mdr will be submitted upon completion of this activity.
 
Event or Problem Description
A user facility biomedical technician (bmt) reported that a fresenius 2008t hemodialysis (hd) machine was experiencing a low conductivity message.It is unknown if the machine prompted with audible alarms.The cond was 10.0 ms/cm.The bmt stated he noticed the cables on the acid pump and bic pump were burned.The bmt was issued a replacement acid pump.It is unknown if the acid or bic pump cables were available to be returned for manufacturer evaluation.There was no patient involvement associated with the reported event.Additional information was requested, however to date has not been provided.
 
Additional Manufacturer Narrative
Plant investigation: no parts were returned to the manufacturer for physical evaluation.Additionally, no on-site evaluation was performed by a fresenius field service technician (fst).A records review was performed on the reported serial number.An investigation of the device manufacturing records was conducted by the manufacturer.There were no non-conformances, or any associated rework identified during the manufacturing process which could be related to the reported event.In addition, the device history record (dhr) review confirmed the results of the in-progress and final quality control (qc) testing met all requirements.The investigation into the cause of the reported problem was not able to be confirmed.A definitive conclusion regarding the complaint incident cannot be reached without a physical examination of the complaint device.
 
Event or Problem Description
A user facility biomedical technician (bmt) reported that a fresenius 2008t hemodialysis (hd) machine was experiencing a low conductivity message.It is unknown if the machine prompted with audible alarms.The cond was 10.0 ms/cm.The bmt stated he noticed the cables on the acid pump and bic pump were burned.The bmt was issued a replacement acid pump.It is unknown if the acid or bic pump cables were available to be returned for manufacturer evaluation.There was no patient involvement associated with the reported event.Additional information was requested, however to date has not been provided.
 
Event or Problem Description
A user facility biomedical technician (bmt) reported that a fresenius 2008t hemodialysis (hd) machine was experiencing a low conductivity message.It is unknown if the machine prompted with audible alarms.The cond was 10.0 ms/cm.The bmt stated he noticed the cables on the acid pump and bic pump were burned.The bmt was issued a replacement acid pump.It is unknown if the acid or bic pump cables were available to be returned for manufacturer evaluation.There was no patient involvement associated with the reported event.Additional information was requested, however to date has not been provided.
 
Additional Manufacturer Narrative
Correction: g2.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
2008T HEMODIALYSIS SYSTEM WITHOUT CDX
Common Device Name
DIALYZER, HIGH PERMEABILITY WITH OR WITHOUT SEALED DIALYSATE SYSTEM
Manufacturer (Section D)
CONCORD MANUFACTURING
director, quality systems
4040 nelson avenue
concord CA 94520
MDR Report Key12053201
Report Number2937457-2021-01309
Device Sequence Number3464555
Product Code KDI
UDI-Device Identifier00840861100903
UDI-Public00840861100903
Combination Product (Y/N)N
Initial Reporter StateNJ
Initial Reporter CountryUS
PMA/510(K) Number
K113427
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source consumer,health professional
Initial Reporter Occupation Biomedical Engineer
Type of Report Initial,Followup,Followup
Report Date (Section B) 07/08/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number190858
Device Catalogue Number190858
Was Device Available for Evaluation? No
Device AgeMO
Initial Date Received by Manufacturer 06/11/2021
Supplement Date Received by Manufacturer07/02/2021
07/07/2021
Initial Report FDA Received Date06/23/2021
Supplement Report FDA Received Date07/06/2021
07/08/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-