• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: DEPUY ORTHOPAEDICS INC US SIGMA PLI XLK INS 2.5 15MM; SIGMA KNEE PRIMARY : KNEE TIBIAL INSERT

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

DEPUY ORTHOPAEDICS INC US SIGMA PLI XLK INS 2.5 15MM; SIGMA KNEE PRIMARY : KNEE TIBIAL INSERT Back to Search Results
Model Number 1581-02-115
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Necrosis (1971); Fluid Discharge (2686); Swelling/ Edema (4577); Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581)
Date of Event 05/27/2021
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Product complaint #: (b)(4).If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event or Problem Description
Clinical adverse event received for recurrent drainage from incisional area : infection on (b)(6) 2021, the patient presented for a clinic visit for an evaluation due to right knee drainage and edema.Cultures revealed staphylococcus epidermidis and candida.On (b)(6) 2021, the patient underwent a right knee revision to address wound drainage, recurrent infection, and edema.The post-operative diagnosis was indicated as recurrent infection while the "findings" section of intra-op note described the infection as chronic.The surgeon noted there was an erosion of the middle portion of the extensor mechanism just at the level of the joint line.(it is indicated the patient previously underwent an extensor mechanism reconstruction in (b)(6) 2020 to address a ruptured extensor mechanism.Captured on (b)(4).) the surgeon also noted removal of necrotic-appearing tissue.All components were removed and were replaced with a sure space femoral spacer and sure space tibial spacer.Two grams of vancomycin and 100 mg of amphotericin were used per batch of cement.Two batches of depuy 2 with gentamicin cement was utilized.The surgeon indicated the patient would be on iv antibiotics post-operatively.There were no indicated intra-operative complications.Date of implantation: (b)(6) 2020.Date of event (onset): (b)(6) 2021.Date of revision: (b)(6) 2021 (right knee).
 
Additional Manufacturer Narrative
Product complaint # (b)(4).Investigation summary : no device associated with this report was received for examination.Depuy synthes considers the investigation closed.Should additional information be received, the information will be reviewed and the investigation may be re-opened as necessary.Device history lot : the product investigation found no evidence suspecting an error in the manufacturing or material that would be a contributing factor in the reported allegation(s).Where the product and lot code was provided, a manufacturing records evaluation (mre) was not performed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SIGMA PLI XLK INS 2.5 15MM
Common Device Name
SIGMA KNEE PRIMARY : KNEE TIBIAL INSERT
Manufacturer (Section D)
DEPUY ORTHOPAEDICS INC US
700 orthopaedic drive
warsaw IN 46581 0988
MDR Report Key12121164
Report Number1818910-2021-14315
Device Sequence Number11704398
Product Code JWH
UDI-Device Identifier10603295062455
UDI-Public10603295062455
Combination Product (Y/N)N
Initial Reporter StateCO
Initial Reporter CountryUS
PMA/510(K) Number
K943462
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2020
Device Explanted Year2021
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source health professional,study
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 06/04/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model Number1581-02-115
Device Catalogue Number158102115
Device Lot Number8586299
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 06/15/2021
Supplement Date Received by Manufacturer08/03/2021
Initial Report FDA Received Date07/06/2021
Supplement Report FDA Received Date08/03/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
DEPUY CMW 1 40G; PFC*SIGMA C/R NPOR FE RT SZ2.5; SIG MOD TIB TRAY CEM COCR 2.5; SIGMA PLI XLK INS 2.5 15MM; DEPUY CMW 1 40G; PFC*SIGMA C/R NPOR FE RT SZ2.5; SIG MOD TIB TRAY CEM COCR 2.5; SIGMA PLI XLK INS 2.5 15MM
Outcome Attributed to Adverse Event Required Intervention;
Patient Age81 YR
Patient Weight93
-
-