Product complaint # (b)(4).Complainant part is expected to be returned for manufacturer review/investigation but has yet to be received.The investigation could not be completed, no product was received; no conclusion could be drawn at the time of filing this report.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|
It was reported that on an unknown date, the patient underwent removal of a broken titanium cannulated proximal femoral nailing system (tfna) nail at the screw/nail junction.It was unknown if the removal surgery completed successfully.There was patient consequence reported.Concomitant devices reported: unknown tfna helical blade (part# unknown, lot# unknown, quantity 1).Unknown tfna end cap (part# unknown, lot# unknown, quantity 1).Unknown nail distal locking screw (part# unknown, lot# unknown, quantity 1).This complaint involves one (1) device.This report is for (1) 12mm/125 deg ti cann tfna 170mm - sterile.This report is 1 of 1 for (b)(4).
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.H10 additional narrative: h6: product was not returned.Based on the information available, it has been determined that no corrective and preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable h6: a device history record (dhr) review was conducted: manufacturing location: monument.Manufacturing date: 24-jul-2019.Expiration date: 30-jun-2029.Part number: 04.037.212s, 12mm/125 deg ti cann tfna 170mm - sterile.Lot number: 12l5265 (sterile).Lot quantity: (b)(4).Production order traveler met all inspection acceptance criteria.Inspection sheet, in-process / inspect dimensional / final met all inspection acceptance criteria.Inspection sheet, tfna assembly inspection met all inspection acceptance criteria.Packaging label log (pll) was reviewed and determined to be conforming.Packaging bom was reviewed and found to be conforming with no deviations to normal packaging identified.Scn supplied by (b)(4) (abq) was reviewed and determined to be conforming.This lot met all dimensional, visual, sterility and packaging criteria at the time of release with no issues documented during the manufacture that would contribute to this complaint condition.Component part(s) reviewed: part number: 04.037.912.2, lock prong, 125 degree, tfna.Lot number: 4l03575.Lot quantity: (b)(4).Production order traveler met all inspection acceptance criteria.Part number: 04.037.912.4, wave spring, shim ended.Lot number: h795853.Lot quantity: (b)(4).Work order traveler met all inspection acceptance criteria.Inspection sheet, incoming final inspection, met all inspection acceptance criteria.Material certificate and certificate of conformance and quality history card received from (b)(4) dated 19-feb-2019 were reviewed and determined to be conforming.Part number: 04.037.912.3, tfna lock drive.Lot number: 3l44136.Lot quantity: (b)(4).Production order traveler met all inspection acceptance criteria.Inspection sheet, met all inspection acceptance criteria.Part number: 21127, timoagri16.00, bp80.Lot number: 3l28792.Lot quantity: (b)(4) lbs.Inspection instruction met all inspection acceptance criteria.Certificate of analysis dated 09-apr-2019 was reviewed and determined to be conforming.Lot summary report dated 17-may-2019 met all inspection acceptance criteria.Raw material receiving/putaway checklist met all inspection acceptance criteria.This lot met all dimensional, visual, sterility and packaging criteria at the time of release with no issues documented during the manufacture that would contribute to this complaint condition.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|