• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: DEPUY ORTHOPAEDICS INC US GLOBAL ADVANTAGE ECC HD 52X18; GLOBAL ADVANTAGE IMPLANT : SHOULDER HUMERAL HEADS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

DEPUY ORTHOPAEDICS INC US GLOBAL ADVANTAGE ECC HD 52X18; GLOBAL ADVANTAGE IMPLANT : SHOULDER HUMERAL HEADS Back to Search Results
Model Number 1128-52-110
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Pocket Erosion (2013)
Date of Event 06/15/2021
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Product complaint #: (b)(4).If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event or Problem Description
Original surgery right hemi arthroplasty using global advantage stem and head.Revision surgery (b)(6) 2021.(b)(6).Reason for revision -glenoid erosion.
 
Additional Manufacturer Narrative
Product complaint # (b)(4).Investigation summary: no device associated with this report was received for examination.The information received will be retained for potential series investigations if triggered by trend analysis, post market surveillance, or other events within the quality system.Depuy considers the investigation closed.Should additional information be received, the information will be reviewed and the investigation will be re-opened as necessary.Device history lot: the product investigation found no evidence suspecting an error in the manufacturing or material that would be a contributing factor in the reported allegation(s).A manufacturing records evaluation (mre) was not performed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
GLOBAL ADVANTAGE ECC HD 52X18
Common Device Name
GLOBAL ADVANTAGE IMPLANT : SHOULDER HUMERAL HEADS
Manufacturer (Section D)
DEPUY ORTHOPAEDICS INC US
700 orthopaedic drive
warsaw IN 46581 0988
MDR Report Key12161124
Report Number1818910-2021-15077
Device Sequence Number3577465
Product Code HSD
UDI-Device Identifier10603295005223
UDI-Public10603295005223
Combination Product (Y/N)N
Initial Reporter CountryUK
PMA/510(K) Number
K992065
Number of Events Summarized1
Summary Report (Y/N)N
Device Explanted Year2021
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source foreign,health professional
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 06/15/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model Number1128-52-110
Device Catalogue Number112852110
Device Lot NumberCS1DM1000
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 06/15/2021
Supplement Date Received by Manufacturer08/26/2021
Initial Report FDA Received Date07/13/2021
Supplement Report FDA Received Date08/27/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
GLOBAL ADVANTAGE ECC HD 52X18; GLOBAL ADVANTAGE STEM 12 MM
Outcome Attributed to Adverse Event Required Intervention;
Patient Age60 YR
-
-