• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: WRIGHTS LANE SYNTHES USA PRODUCTS LLC TI LOCKING SCREW; ORTHOSIS, CERVICAL PEDICLE SCREW SPINAL FIXATION

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

WRIGHTS LANE SYNTHES USA PRODUCTS LLC TI LOCKING SCREW; ORTHOSIS, CERVICAL PEDICLE SCREW SPINAL FIXATION Back to Search Results
Model Number 04.614.508
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Spinal Cord Injury (2432)
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Additional narrative: complainant part is not expected to be returned for manufacturer review/investigation.Reporter is a synthes employee.Without a lot number the device history records review could not be completed.Product was not returned.Based on the information available, it has been determined that no corrective and/or preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.".
 
Event or Problem Description
This report is being filed after the review of a clinical evaluation report (cer) from a related research activity database (ddra) for patients undergoing cervical fusion.The following complications were reported: readmission: neoplasm, benign, nos (1) -patient no.(b)(6), male, (b)(6) years old who underwent posterior c3-t2 decompression for tumor resection and fusion with synapse instrumentation readmitted for neoplasm, benign, nos.Neoplasm, metastatic, brain/spinal cord (1) -patient no.(b)(6), female, (b)(6)-year-old who underwent posterior cervicothoracic decompression fusion was readmitted for neoplasm, metastatic, brain/spinal cord.Stenosis, cervical spine (3) -patient (no.(b)(6))female (b)(6)-year-old who underwent anterior c5-c6, c6-7 discectomy and fusion with allograft and aviator plate was readmitted due to stenosis, cervical spine.-patient (no (b)(6)) female (b)(6)-year-old who underwent anterior c5-6, c6-7 discectomy and fusion with allograft and aviator plate was readmitted due to stenosis, cervical spine.-patient (no.(b)(6)) female (b)(6)-year-old who underwent anterior/posterior cervical fusion was readmitted due to stenosis, cervical spine.Stenosis, cervicothoracic spine (1) -patient (no.(b)(6)) female (b)(6)-year-old who underwent anterior l3-s1 decompression fusion with vertigraft, possible infuse was readmitted due to stenosis, cervicothoracic spine.Spondylosis without myelopathy or radiculopathy, cervical region (2) -patient (no.(b)(6)) female (b)(6)-year-old who underwent posterior cervical c5-6 decompression and fusion with synapse instrumentation was readmitted due to spondylosis without myelopathy or radiculopathy, cervical region.-patient no.(b)(6) male (b)(6)-year-old who underwent posterior c3-7 decompression was readmitted due to spondylosis without myelopathy or radiculopathy, cervical region.Other spondylosis with myelopathy, cervical region (4) -patient no (b)(6) female (b)(6)-year-old who underwent revision anterior c7 corpectomy was readmitted due to other spondylosis with myelopathy, cervical region.-patient no (b)(6) male (b)(6)-year-old who underwent posterior cervical c2-7 decompresion was readmitted due to other spondylosis with myelopathy, cervical region.-patient (no.(b)(6))male (b)(6)-year-old who underwent anterior c5-6, c6-7 decompression fusion with vg2 and maxan plate/posterior c2-t2 decompression fusion with synapse 4.0 instrumentation(new aesculap retractor) was readmitted due to other spondylosis with myelopathy, cervical region.-patient no (b)(6) female (b)(6)-year-old who underwent posterior c3-7 decompression f was readmitted due to other spondylosis with myelopathy, cervical region.Spondylosis with myelopathy, cervical region (3) -patient no (b)(6), female, (b)(6)-year-old who underwent anterior c3-7 decompression fusion with allograft/posterior c3-t1 fusion with synapse was readmitted due to spondylosis with myelopathy, cervical region.-patient no (b)(6), female, (b)(6)-year-old who underwent anterior c3-7 decompression fusion with allograft/posterior c3-t1 fusion with synapse was readmitted due to spondylosis with myelopathy, cervical region.-patient no (b)(6), male, (b)(6)-year-old who underwent anterior/posterior cervical decompression and fusion was readmitted due to spondylosis with myelopathy, cervical region.Spondylosis with myelopathy, thoracic region (1) -patient no (b)(6), male, (b)(6)-year-old who underwent posterior cervical fusion c3-t2 was readmitted due to spondylosis with myelopathy, thoracic region.Radiculopathy, cervical region (1) -patient no (b)(6) male (b)(6)-year-old who underwent posterior c4-t1 decompression was readmitted due to radiculopathy, cervical region.Other cord compression (1) -patient no (b)(6), male, (b)(6)-year-old who underwent posterior c2-6 decompression and fusion with synapse 4.0 instrumentation was readmitted due to other cord compression.Myelopathy, nec (1) -patient no (b)(6), male ,(b)(6)-year-old who underwent anterior/posterior cervical corpectomy and fusion; i and d; graft placement was readmitted due to myelopathy, nec.Connective tissue and disc stenosis of intervertebral forami (1) -patient no (b)(6), male, (b)(6)-year-old who underwent posterior cervical decompression was readmitted due to connective tissue and disc stenosis of intervertebral forami.Other cervical disc displacement (1) -patient no (b)(6),female, (b)(6)-year-old who underwent posterior c3-t1 decompression was readmitted due to other cervical disc displacement.Kyphosis, unspecified, cervical region (1) -patient no (b)(6), male, (b)(6)-year-old who underwent posterior c2-4 fusison with 3.5 synapse instrumentation was readmitted due to kyphosis, unspecified, cervical region.Postural kyphosis, cervicothoracic region (1) -patient no (b)(6), male, (b)(6)-year-old who underwent anterior c3-t1 decompression was readmitted due to postural kyphosis, cervicothoracic region.Other postoperative infection (3) -patient no (b)(6) male (b)(6)-year-old who underwent posterior c3-t1 decompression, c3-t2 fusion with syynpase 4.0 instrumentation was readmitted due to other postoperative infection.-patient no (b)(6), female, (b)(6)-year-old who underwent posterior c5-6 6-7 decompression and fusion with synthes synapse and small infuse kit was readmitted due to other postoperative infection.-patient no.(b)(6), male, (b)(6)-year-oldwho underwent c3-7 laminectomy , c3-t1 fusion with synthes synapse instrumentation was readmitted due to other postoperative infection.Infection following a procedure, initial encounter (2) -patient no (b)(6),male, (b)(6)-year-old who underwent posterior cervical c3-7 decompression was readmitted due to infection following a procedure, initial encounter.-patient no (b)(6),male, (b)(6)-year-old who underwent minimally invasive posterior c was readmitted due to infection following a procedure, initial encounter.Infection and inflammatory reaction due to internal fixation (1) -patient no (b)(6).Female, (b)(6)-year-old who underwent posterior c2-t1 fusion with sy was readmitted due to infection and inflammatory reaction due to internal fixation.Pseudarthrosis after fusion or arthrodesis (5) -patient no (b)(6),male, (b)(6)-year-old who underwent posterior c1-2 decompression was readmitted due to pseudarthrosis after fusion or arthrodesis.-patient no (b)(6),male, (b)(6)-year-old who underwent image guided revision posterior was readmitted due to pseudarthrosis after fusion or arthrodesis.-patient no (b)(6) male (b)(6)-year-old who underwent posterior c3-7 decompression was readmitted due to pseudarthrosis after fusion or arthrodesis.-patient no (b)(6), female, (b)(6)-year-old who underwent revision posterior cervical fusion was readmitted due to pseudarthrosis after fusion or arthrodesis.-patient no (b)(6), female, (b)(6)-year-old who underwent revision posterior c2-7 decompression was readmitted due to pseudarthrosis after fusion or arthrodesis.Displacement of other internal orthopedic devices, implants (1) -patient no (b)(6),male, (b)(6) year old who underwent anterior posterior cervical th rod spinal 80mm 3.5mm axon cur readmitted due to displacement of other internal orthopedic devices, implants.Other mechanical complication of other internal orthopedic device (1) -patient no.(b)(6),male, (b)(6) year old who underwent anterior c3-6 decompression fu was readmitted due to other mechanical complication of other internal orthopedic device.Complication nec due to other internal orthopedic device (1) -patient no.(b)(6),female ,(b)(6) year old who underwent anterior cervical c4-6 corpectomy with fibula allograft, posterior c3-t1 laminectomy and fusion with synapse 4.0 instrumentation was readmitted due to complication nec due to other internal orthopedic device mechanical complication internal orthopedic device/implant/graft, nec (1) -patient no (b)(6),female, (b)(6) year old ,who underwent removal of anterior bilateral was readmitted due to mechanical complication internal orthopedic device/implant/graft, nec mechanical complication internal orthopedic device/implant/graft, nos (1) -patient no (b)(6),female, (b)(6)-year-old who underwent posterior c3-7 decompression, c3-t1 fusion with synapse 3.5 instrument (latex allergy) was readmitted due to mechanical complication internal orthopedic device/implant/graft, nos.Neuralgia/neuritis, nos (1) -patient no (b)(6) male, (b)(6)-year-old who underwent posterior cervical fusion was readmitted due to neuralgia/neuritis, nos.Spondylolisthesis, acquired (1) -patient no.(b)(6),male, (b)(6) year-old who underwent posterior c3-7 decompression, c3-t1 fusion with synthes synapse instrumentation was readmitted due to spondylolisthesis, acquired.Non-healing surgical wound (1) -patient no (b)(6),male, (b)(6)-year-old who underwent anterior c3-4, c4-5, c6-7 decompression and fusion with allograft, (no plate), posterior c3-7 laminectomy, c3-t1 fusion with synthes synapse 4.0 instrumentation was readmitted due to non-healing surgical wound.Disruption of external operation (surgical) wound, not elsewhere classified (1) -patient no (b)(6),female, (b)(6)-year-old who underwent occiput to c2 decompression and fusion was readmitted due to disruption of external operation (surgical) wound, not elsewhere classified.Nontraumatic extradural hemorrhage (1) -patient no (b)(6) male (b)(6)-year-old who underwent posterior c3-t1 decompression was readmitted due to nontraumatic extradural hemorrhage.Fx closed c3 vertebra (2) -patient no (b)(6),male ,(b)(6)-year-old who underwent anterior c3-4, c4-5, c5-6, c6-7 decompression and fusion with allograft (no plate), posterior c3-t1 fusion with synthes synapse 4.0 was readmitted due to fx closed c3 vertebra.-patient no (b)(6),male, (b)(6)-year-old who underwent revision a/p cervical decompression/fusion was readmitted due to fx closed c3 vertebra.Fx closed c2 vertebra (1) -patient no (b)(6),female, (b)(6)-year-old who underwent posterior c5-t1 decompression fusion with synthes synapse instrumentation was readmitted due to fx closed c2 vertebra.Other fracture of first thoracic vertebra (1) -patient no (b)(6),male, (b)(6)-year-old who underwent anterior/ posterior c4-7 dec was readmitted due to other fracture of first thoracic vertebra.Unstable burst fracture of first thoracic vertebra (1) -patient no (b)(6),male, (b)(6)-year-old who underwent panendoscopy with poss neck exploration was readmitted due to unstable burst fracture of first thoracic vertebra.Removal of clik-x instrumentation (1) -patient no.(b)(6), (b)(6) year old male had removal of l4-s1 clik-x instrumentation.-the following patient had removal of synapse system implants (6) patient no.(b)(6) male (b)(6) years old underwent posterior removal of synapse rods revision of t1 screws, placement of t2-t4 screws/anterior c6-7, c7-t1 fusion with allograft /posterior implantation of synapse rods -patient no.(b)(6) male (b)(6) years old underwent posterior removal of synapse rods, revision of fusion to t4/anterior c7-t1 corpectomy fusion with tricortical allograft.Readmitted for myelopathy nec.-patient no.(b)(6) female (b)(6)-year-old underwent revision anterior/posterior decompression and fusion , removal of cslp plate and synapse instrumenatation , reinstrumentation with atlantis and mountaineer vs.Cslp and synapse.-patient no.(b)(6), female , (b)(6)-year-old who underwent posterior c1-2 fusion with mountaineer , removal of synthes instrumentation.-patient no.(b)(6), (b)(6) yo female, revision of occiput-c4 fusion with revision of synthes synapse.-patient no.(b)(6), (b)(6) yo female, removal of synapse c4-t1 rods.-the following had removal of cervifix implants (3) patient no.(b)(6) male (b)(6) years old underwent revision posterior c2-t2 fusion with synapse instrumentation and autograft (remove cervifix) -patient no.(b)(6), male (b)(6)-year-old who underwent revison anterior c5-6 decompression fusion with allograft and vectra plate (remove synthes cslp) , posterior revision c2-t1 with synapse instrumenataton (remove cervifix)s.-patient no.(b)(6),female, (b)(6)-year-old, who underwent cervical decompression and fusion (no plate) , revision posterior cervical fusion with synthes synapse, removal of synthes cervifix screws the following had removal of cslp (3 refer to pt (b)(6)) -patient no.(b)(6) female (b)(6) years old had removal anterior c3-7 cslp plate.This is for depuy synthes posterior cervical systems (synapse).This is report 8 of 17 for (b)(4).Additional reports are captured under (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TI LOCKING SCREW
Common Device Name
ORTHOSIS, CERVICAL PEDICLE SCREW SPINAL FIXATION
Manufacturer (Section D)
WRIGHTS LANE SYNTHES USA PRODUCTS LLC
1302 wrights lane east
west chester PA 19380
MDR Report Key12169617
Report Number2939274-2021-04089
Device Sequence Number11707860
Product Code NKG
UDI-Device Identifier10705034739229
UDI-Public10705034739229
Combination Product (Y/N)N
Initial Reporter CountryUS
PMA/510(K) Number
K142838
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source company representative,study
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 06/14/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model Number04.614.508
Device Catalogue Number04.614.508
Was Device Available for Evaluation? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 06/14/2021
Initial Report FDA Received Date07/14/2021
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age55 YR
-
-