MAUDE Adverse Event Report: CARDINAL HEALTH 12ML LUER LOCK TIP PHARM TRAY; SYRINGE, PISTON

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

CARDINAL HEALTH 12ML LUER LOCK TIP PHARM TRAY; SYRINGE, PISTON Back to Search Results
Model Number 8881512258
Medical Device Problem Code Device Contaminated During Manufacture or Shipping (2969)
Health Effect - Clinical Codes Insufficient Information (4580); No Clinical Signs, Symptoms or Conditions (4582)
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The incident sample has been requested but to date has not been received for evaluation.  if the sample is received, or if additional information pertinent to the incident is obtained a follow-up report will be submitted.  as part of our manufacturing process, all device history records are reviewed and approved by quality, prior to release of product.
 
Event or Problem Description
Customer reports: when filling the syringes, there are black particles found in some of the syringes and white particles in other syringes from the lot.The customer sent the product to a 3rd party lab for analysis and the white fibers were identified as cellulose with silicone and oxygen-rich surface particles and the black fiber defects were identified as textile cotton fibers with spectral indications of silicone.
 
Additional Manufacturer Narrative
A device history record revealed no abnormal process conditions were present during the manufacturing of the product that could have led to the condition described by the customer.The device history record review showed that all acceptance criteria inspections per established sampling levels were within acceptable limits during the production process.Six photos were provided for review.In 2 of the photos it is observed that the syringe has contamination.One physical monoject syringe with 12ml liquid without the original package or lot number identification was also received for evaluation.The component is produced by an external supplier and the assembly process consists of a pick and place operation at the cardinal health facility.The root cause for the condition was requested from the manufacturer.The results are currently pending.There is no additional inspection on the line to detect the reported condition.We are awaiting an action plan to be implement by the supplier for the corrective actions.The cardinal health facility will continue monitoring the process for any adverse trends that require immediate attention.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
12ML LUER LOCK TIP PHARM TRAY
Common Device Name
SYRINGE, PISTON
Manufacturer (Section D)
CARDINAL HEALTH
calle 9 sur no. 125 cuidad ind
tijuana 22500
MX  22500
MDR Report Key12170143
Report Number9612030-2021-02982
Device Sequence Number17324566
Product Code FMF
UDI-Device Identifier10884521010970
UDI-Public10884521010970
Combination Product (Y/N)N
Initial Reporter StateCA
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,distri
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 10/22/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device No Information
Device Model Number8881512258
Device Catalogue Number8881512258
Device Lot Number2030104764
Initial Date Received by Manufacturer 07/06/2021
Supplement Date Received by Manufacturer07/06/2021
Initial Report FDA Received Date07/14/2021
Supplement Report FDA Received Date10/22/2021
Patient Sequence Number1
-
-