CORDIS CORPORATION TRAPEASE PVCF FEM/JUG 55CM CSI; FILTER, INTRAVASCULAR, CARDIOVASCULAR
|
Back to Search Results |
|
Model Number 466P306X |
Device Problem
Adverse Event Without Identified Device or Use Problem (2993)
|
Patient Problems
Perforation (2001); Perforation of Vessels (2135); No Clinical Signs, Symptoms or Conditions (4582)
|
Event Date 06/28/2019 |
Event Type
Injury
|
Manufacturer Narrative
|
It was reported that a patient underwent placement of a trapease vena cava filter.The information provided indicated that the filter subsequently malfunctioned and caused perforation of the filter and the resultant symptoms.The indication for the filter implant has not been provided and there is currently no additional information available for review.The product was not returned for analysis and the sterile lot number has not been provided; therefore, no device analysis nor device history record review could be performed.The trapease ivc filter is indicated for use in the prevention of recurrent pulmonary embolism (pe) via percutaneous placement in the vena cava for patients in which anticoagulants are contraindicated, anticoagulant therapy for thromboembolic disease has failed, emergency treatment following massive pe where anticipated benefits of conventional therapy are reduced or for chronic, recurrent pe where anticoagulant therapy has failed, or is contraindicated.The purpose of a vena cava filter is to catch thrombus from the lower extremities as it travels along normal blood flow patterns up towards the heart.Vessel perforation is a known adverse event associated with implanting vena cava filters and is listed as such in the instructions for use (ifu).The ifu also notes vessel damage such as intimal tears and perforation as procedural and long-term complications related to ivc filters.Without procedural films or post implant imaging available for review, the reported filter perforation could not be confirmed or further clarified.There is nothing to suggest that the reported event is related to the design and/or manufacturing process of the device; therefore, no corrective action will be taken.Should additional information become available, the file will be updated accordingly.
|
|
Event Description
|
As reported by the legal department, the patient underwent placement of the trapease vena cava filter.The filter subsequently malfunctioned and caused injury and damages to the patient including, but not limited to, perforation of the filter and the resultant symptoms.As a direct and proximate result, the patient suffered life-threatening injuries and damages and required extensive medical care and treatment.As a further proximate result, the patient has suffered and will continue to suffer significant medical expenses, pain and suffering, and other damages.
|
|
Manufacturer Narrative
|
It was reported that a patient underwent placement of a trapease vena cava filter.The information provided indicated that the filter subsequently malfunctioned and caused perforation of the filter and the resultant symptoms.The patient reported becoming aware of perforation of filter strut(s) outside the inferior vena cava (ivc), approximately seven years and five months post implant.The patient also reported mental anguish related to the filter.Approximately seven years and five months post implant an abdominal computed tomography (ct) scan was done to evaluate the filter.The images revealed that the cephalad tip of the filter was located approximately 1 cm below the renal veins.There was a 1 mm perforation of the body and struts of the filter in the anterior, posterior, medial and lateral directions.The indication for the filter implant has not been provided and there is currently no additional information available for review.The product was not returned for analysis and the sterile lot number has not been provided; therefore, no device analysis nor device history record review could be performed.The trapease ivc filter is indicated for use in the prevention of recurrent pulmonary embolism (pe) via percutaneous placement in the vena cava for patients in which anticoagulants are contraindicated, anticoagulant therapy for thromboembolic disease has failed, emergency treatment following massive pe where anticipated benefits of conventional therapy are reduced or for chronic, recurrent pe where anticoagulant therapy has failed, or is contraindicated.The purpose of a vena cava filter is to catch thrombus from the lower extremities as it travels along normal blood flow patterns up towards the heart.Vessel perforation is a known adverse event associated with implanting vena cava filters and is listed as such in the instructions for use (ifu).The ifu also notes vessel damage such as intimal tears and perforation as procedural and long-term complications related to ivc filters.Without procedural films or post implant imaging available for review, the reported filter perforation could not be confirmed or further clarified.Anxiety is an emotion characterized by an unpleasant state of inner turmoil, often accompanied by nervous behavior, somatic complaints, and rumination.The physiological symptoms of anxiety may include, but are not limited to neurological, respiratory, cardiac, muscular, and cutaneous.These symptoms of anxiety do not represent a device malfunction and may be related to underlying patient specific issues.There is nothing to suggest that the reported event is related to the design and/or manufacturing process of the device; therefore, no corrective action will be taken.Should additional information become available, the file will be updated accordingly.
|
|
Event Description
|
Additional information received per the patient profile form (ppf) states that the patient experienced perforation of filter strut(s) outside the inferior vena cava (ivc).The patient became aware of the reported event approximately seven years and five months after the index procedure.The patient continues to experience mental anguish.Approximately seven years and five months after the index procedure an abdominal computed tomography (ct) scan was done to evaluate the filter.The images revealed that the cephalad tip of the filter was located approximately 1 cm below the renal veins.There was a 1 mm perforation of the body and struts of the filter in the anterior, posterior, medial and lateral directions.
|
|