| Model Number |
3CX*FX15RE40C |
| Medical Device Problem Code |
Device Damaged Prior to Receipt by User (1570)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
06/30/2021
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Terumo has not received the device for evaluation; therefore, the investigation has yet to be completed.Terumo plans on submitting a follow-up report when the investigation is complete and when more information becomes available.(b)(4).
|
| |
|
Event or Problem Description
|
|
The user facility reported to terumo cardiovascular that prior to cardiopulmonary bypass, during out of box, the customer opens the wrong oxygenator pack.Instead of receiving a fx25 the customer received a fx15re40.No patient involvement.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is submitted, to fda in accord with applicable regulations.And as indicated, by terumo cardiovascular systems in the initial report submitted to the fda on july 15, 2021.Upon further investigation of the reported event, the following information is new and/or changed: d9: (device availability, added date returned to manufacturer).G3: (date received by manufacturer).G6: (indication that this is a follow-up report).H2: (follow-up, due to additional information).H3: (device evaluation anticipated by manufacturer.A second follow-up will be submitted, upon completion of the investigation and/or submission of new information.Thus, tcvs references conclusions code 11).All available information has been placed on file in quality management for appropriate tracking, trending, and follow-up.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is submitted to fda in accord with applicable regulations.Upon further investigation of the reported event, the following information is new and/or changed: d4 (additional device information - added expiration date); g3 (date received by manufacturer); g6 (indication that this is a follow-up report); h2 (follow-up due to additional information and device evaluation); h3 (device evaluated by manufacturer); h4 (device manufacture date); h6 (identification of evaluation codes 10, 3331, 170, 4315).Type of investigation: #1: 10 - testing of actual/suspected device.Type of investigation #2: 3331 - analysis of production records.Investigation findings: 170 - manufacturing process problem identified.Investigation conclusions: 4315 - cause not established.The affected sample was inspected upon receipt to confirm a fx15 was inside of a fx25 package.It is unknown exactly when or how this event occurred.The most likely cause of this issue is handling after the units left tcv control as applicable part, label and serial number counts were found to be correct with the applicable finished work orders.All available information has been placed on file in quality management for appropriate tracking, trending, and follow-up.
|
| |
|