• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: WRIGHTS LANE SYNTHES USA PRODUCTS LLC TI LCP(TM) DISTAL FEMUR PLATE 11 HOLES/276MM-RIGHT; PLATE, FIXATION, BONE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

WRIGHTS LANE SYNTHES USA PRODUCTS LLC TI LCP(TM) DISTAL FEMUR PLATE 11 HOLES/276MM-RIGHT; PLATE, FIXATION, BONE Back to Search Results
Model Number 422.256
Medical Device Problem Codes Device-Device Incompatibility (2919); Migration (4003)
Health Effect - Clinical Codes Pain (1994); No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/01/2021
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Complainant part is not expected to be returned for manufacturer review/investigation.Reporter is a synthes employee.Without a lot number the device history records review could not be completed.Product was not returned.Based on the information available, it has been determined that no corrective and/or preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event or Problem Description
It was reported that during a procedure on an unknown date, the screws either backed out or were broken.The patient was revised with another plate.Procedure was with an unknown delay.Patient outcome is unknown.This report is for a titanium (ti) locking compression plate (lcp) distal femur plate.This is report 1 of 2 for (b)(4).
 
Additional Manufacturer Narrative
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.H10 additional narrative: the complaint condition was not confirmed for the ti lcp(tm) dstl femur pl 11 holes/276-rt (p/n: 422.256 & lot #: l658013).During the investigation, no product design issues or discrepancies were observed.No manufacturing issues were noted during investigation.Additional monitoring for any potential safety signals will be conducted through complaint trending and other post market safety surveillance activities.Therefore, it has been determined that no corrective and/or preventive action is proposed.Device history lot : as per jde, the manufactured date for device is 10-jan-2018.A manufacturing-related potential cause was not suspected, therefore, per franchise complaint product investigation procedure 100673626 no manufacturing record evaluation is required.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TI LCP(TM) DISTAL FEMUR PLATE 11 HOLES/276MM-RIGHT
Common Device Name
PLATE, FIXATION, BONE
Manufacturer (Section D)
WRIGHTS LANE SYNTHES USA PRODUCTS LLC
1302 wrights lane east
west chester PA 19380
MDR Report Key12205073
Report Number2939274-2021-04195
Device Sequence Number17253301
Product Code HRS
UDI-Device Identifier10886982215444
UDI-Public(01)10886982215444
Combination Product (Y/N)N
Initial Reporter CountryUS
PMA/510(K) Number
K062564
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2021
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source company representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 06/22/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number422.256
Device Catalogue Number422.256
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer07/28/2021
Initial Date Received by Manufacturer 06/22/2021
Supplement Date Received by Manufacturer08/19/2021
Initial Report FDA Received Date07/21/2021
Supplement Report FDA Received Date08/20/2021
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
5.0 TI LOCKING SCREW SELF-DRILLING 40
Patient Age79 YR
Patient Weight123
-
-