Model Number RHA-S2
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Pain (1994); Loss of Range of Motion (2032)
Date of Event 01/14/2017
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
The device will not be returned.If additional information becomes available, it will be provided in a supplemental report.
 
Event or Problem Description
A patient reported that five months post left radial head arthroplasty for comminuted radial head fracture they developed increasing pain and loss range of motion.Surgeons found patient had a grossly radial head implant when weight bearing of the renal stem.Patient had close to zero pronation and supination and lacking 20 degrees extension.X-rays and revision surgery concluded these findings.Revision surgery was needed 5 months after initial surgery.
 
Additional Manufacturer Narrative
Please note correction to d4 lot number.The reported event could not be confirmed, since the device was not returned for evaluation and no other evidences were provided.The device inspection was not possible as the product was not returned for investigation.A review of the device history for the reported lot did not indicate any abnormalities.No corrective actions are required at this time.A review of the labeling did not indicate any abnormalities.The instructions for use instructs user that: ¿strenuous loading, excessive mobility, and articular instability all may lead to accelerated wear and eventual failure by loosening, fracture, or dislocation of the device.Patients should be made aware of the increased potential for device failure if excessive demands are made upon it.Adverse effects may necessitate reoperation, revision, or fusion of the involved joint.While the expected life of joint replacement components is difficult to estimate, it is finite.These components are made of foreign materials which are placed within the body for the potential restoration of mobility or reduction of pain.However, due to the many biological, mechanical and physiochemical factors which affect these devices, the components cannot be expected to withstand the activity level and loads of normal healthy bone for an unlimited period of time.¿ more detailed information about the complaint event as well as the affected device must be available in order to determine the root cause of the complaint event.If device is returned or any further information is provided, the investigation report will be reassessed.
 
Event or Problem Description
A patient reported that five months post left radial head arthroplasty for comminuted radial head fracture they developed increasing pain and loss range of motion.Surgeons found patient had a grossly radial head implant when weight bearing of the renal stem.Patient had close to zero pronation and supination and lacking 20 degrees extension.X-rays and revision surgery concluded these findings.Revision surgery was needed 5 months after initial surgery.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
RADIAL STEM IMPLANT #2 (STERILE PACKED)
Common Device Name
ELBOW JOINT RADIAL (HEMI-ELBOW) POLYMER PROSTHESIS
Manufacturer (Section D)
STRYKER GMBH
bohnackerweg 1
postfach
selzach 2545
SZ  2545
Manufacturer (Section G)
STRYKER GMBH
bohnackerweg 1
postfach
selzach 2545
SZ   2545
Manufacturer Contact
marilyne chaumont
325 corporate drive
mahwah, NJ 07430
2018315000
MDR Report Key12249540
Report Number0008031020-2021-00328
Device Sequence Number20045532
Product Code KWI
UDI-Device Identifier00886385024721
UDI-Public00886385024721
Combination Product (Y/N)N
Initial Reporter CountryUS
PMA/510(K) Number
K002644
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Consumer
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 11/17/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Lay User/Patient
Device Expiration Date10/31/2020
Device Model NumberRHA-S2
Device Catalogue NumberRHAS2
Device Lot Number24994601
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 07/12/2021
Supplement Date Received by Manufacturer10/22/2021
Initial Report FDA Received Date07/29/2021
Supplement Report FDA Received Date11/17/2021
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured11/30/2015
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient SexUnknown
-
-