• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: MEDOS INTERNATIONAL SàRL CH VIPER SYSTEM CORTICAL FIX POLYAXIAL SCREW 5.5 6 X 40MM; ORTHOSIS, SPINAL PEDICLE FIXATION, FOR DEGENERATIVE DISC DISEASE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

MEDOS INTERNATIONAL SàRL CH VIPER SYSTEM CORTICAL FIX POLYAXIAL SCREW 5.5 6 X 40MM; ORTHOSIS, SPINAL PEDICLE FIXATION, FOR DEGENERATIVE DISC DISEASE Back to Search Results
Model Number 186731640
Medical Device Problem Code Material Twisted/Bent (2981)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 07/01/2021
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
: complainant part is not expected to be returned for manufacturer review/investigation.The investigation could not be completed; no conclusion could be drawn, as no product was received.Based on the information available, it has been determined that no corrective and/or preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event or Problem Description
Device report from synthes reports an event in (b)(6) as follows: it was reported that on (b)(6) 2021, during a procedure for tlif in the lumbar spine (5/s1) treating lumbar spondylolisthesis the screw would not tighten at l5 left.The screw threads were stripped.There were no fragment left in the patient¿s body.The procedure was completed with a replacement less than 30-minute surgical delay.This report involves one (1) viper system cortical fix polyaxial screw 5.5 6 x 40mm.This is report 1 of 2 for (b)(4).
 
Additional Manufacturer Narrative
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.H3, h6: the product was returned to us customer quality (cq) for evaluation.The us cq team conducted a visual inspection of the returned device.Visual analysis of the returned sample revealed that 5.5 ti cort fix 6x40mm the threads inside the screw head was warped and distorted.Some of the thread get detached from the head.Scratches were also observed on the screw head.The dimensional inspection was not performed due to the post manufacturing damage.The observed condition of 5.5 ti cort fix 6x40mm in the device was consistent.As part of depuy synthes quality process, all devices are manufactured, inspected, and released to approved specifications.The overall complaint was confirmed as the observed broken condition of the 5.5 ti cort fix 6x40mm.While no definitive root cause could be determined, there is no indication that a design or manufacturing issue has caused the complaint condition and hence the root cause cannot be determined.There was no indication that a design or manufacturing issue contributed to the complaint.Based on the investigation findings, it has been determined that no corrective and/or preventative action is proposed.Additional monitoring for any potential safety signals will be conducted through complaint trending and other post-market safety surveillance activities.Drawing/specifications reviewed: the following drawing reflecting the current and manufacture revision was reviewed: viper ti, cortical fix polyaxial screw, top loading shank; viper cortical fix polyaxial screw shank, ø6 x 25-130, ti; expedium 5.50 rod system polyaxial cap 7.5 mm screw; expedium 5.50 rod system polyaxial head for 7.5 mm screw.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Additional Manufacturer Narrative
Product complaint # (b)(4).Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.H10 additional narrative: h3, h6: investigation summary the photo was returned to us cq for evaluation.The us cq team conducted a visual inspection of the returned device.Visual analysis of the photo revealed that 5.5 ti cort fix 6x40mm the device is deformed.As the device was not returned, an as-received condition could not be assessed, and a dimensional inspection and document/specification review were not completed.As part of depuy synthes quality process, all devices are manufactured, inspected, and released to approved specifications.The overall complaint was confirmed for 5.5 ti cort fix 6x40mm.There is no indication that a design or manufacturing issue has caused the complaint condition and hence the root cause cannot be determined.Based on the investigation findings, it has been determined that no corrective and/or preventative action is proposed.Additional monitoring for any potential safety signals will be conducted through complaint trending and other post-market safety surveillance activities.Device history lot: the dhr of product code: 186731640.Lot : 264379.Was electronically reviewed and no non-conformances.Were observed during the manufacturing process.The product was released on: 11.27.2019.Qty: (b)(4).Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
VIPER SYSTEM CORTICAL FIX POLYAXIAL SCREW 5.5 6 X 40MM
Common Device Name
ORTHOSIS, SPINAL PEDICLE FIXATION, FOR DEGENERATIVE DISC DISEASE
Manufacturer (Section D)
MEDOS INTERNATIONAL SàRL CH
chemin-blanc 38
le locle 02400
SZ  02400
MDR Report Key12253784
Report Number1526439-2021-01586
Device Sequence Number3635867
Product Code NKB
UDI-Device Identifier10705034351827
UDI-Public10705034351827
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K110216
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Physician
Type of Report Initial,Followup,Followup
Report Date (Section B) 07/01/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number186731640
Device Catalogue Number186731640
Device Lot Number264379
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer08/13/2021
Initial Date Received by Manufacturer 07/01/2021
Supplement Date Received by Manufacturer08/23/2021
08/27/2021
Initial Report FDA Received Date07/30/2021
Supplement Report FDA Received Date08/26/2021
09/23/2021
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
UNK - LOCKING/SET SCREWS; UNK - LOCKING/SET SCREWS; UNK - LOCKING/SET SCREWS
-
-