| Model Number |
442027 |
| Medical Device Problem Code |
Incorrect, Inadequate or Imprecise Result or Readings (1535)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
07/28/2021
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
A device evaluation and/or device history review is anticipated, but is not complete.Upon completion, a supplemental report will be filed.
|
| |
|
Event or Problem Description
|
|
It was reported that while using bd bactec¿ standard/10 aerobic/f culture vials 10 false positive results were obtained by the laboratory personnel.A differential test was used to confirm the results as false positives.The customer stated results were not reported out so there was no report of patient impact.The following information was provided by the initial reporter: "blood plate transfer was performed on the specimens in the bottle plastic bactec lytic/10 anaer/f reporting false positive, no bacterial growth was observed after 48 hours of culture.".
|
| |
|
Event or Problem Description
|
|
It was reported that while using bd bactec¿ standard/10 aerobic/f culture vials 10 false positive results were obtained by the laboratory personnel.A differential test was used to confirm the results as false positives.The customer stated results were not reported out so there was no report of patient impact.The following information was provided by the initial reporter: "blood plate transfer was performed on the specimens in the bottle plastic bactec lytic/10 anaer/f reporting false positive, no bacterial growth was observed after 48 hours of culture.".
|
| |
|
Additional Manufacturer Narrative
|
|
H6: investigation: customer reported a false positive defect.Bd was unable to reproduce customer experience with the bactec product.A false positive response was not observed when retention samples were tested.Neither plots nor log files were received.Batch history records were reviewed, and all testing were within specification for product release.Users are cautioned in the package insert under limitation of the procedure: ¿a gram-stained smear from culture medium may contain small number of non-viable organisms derived from media constituents, staining reagents, immersion oil, glass slide and specimens used for inoculation.There are many factors that can influence the false positive rate, including blood volume, blood cell counts, environmental factors, and media lot to lot variations.Complaint is unconfirmed based on retention samples and batch history record review.No correctives actions were required.A cross functional team continually monitors all product complaints for trends and determines if any additional actions are necessary beyond the current investigation process.H3 other text: see h10.
|
| |
|