• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: CENTINEL SPINE, LLC. STALIF MIDLINE ABO SCREW 6 X 35MM; INTERVERTEBRAL FUSION DEVICE WITH INTEGRATED FIXATION, LUMBAR

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

CENTINEL SPINE, LLC. STALIF MIDLINE ABO SCREW 6 X 35MM; INTERVERTEBRAL FUSION DEVICE WITH INTEGRATED FIXATION, LUMBAR Back to Search Results
Model Number STM6035
Medical Device Problem Code Malposition of Device (2616)
Health Effect - Clinical Code Pain (1994)
Date of Event 07/27/2021
Type of Reportable Event Death
Additional Manufacturer Narrative
Information provided from the reporter indicates that the m flx cage was positioned off of midline.After implantation it was indicated the patient was suffering leg pain due to one of the lateral screws protruding into the foramen.The surgeon decided that revision would be needed to correct the pain and device positioning.It's assumed the patient's condition would have been permanent if it were not for surgical intervention.During the revision procedure on (b)(6) 2021, the patients scar tissue led to uncontrollable bleeding from the iliac vein.The patient expired during the revision procedure due to blood loss.The bleeding began while trying to access the lumbar level and mobilize the vein to allow for the 3rd and final screw to be removed from the cage.Dhr did not find any problems that would have contributed to this complaint.Complaint history indicates this is the 1st instance of an anterior lumbar revision resulting in death.This is also the 1st indication of an m flx cage being off midline and/or a screw protruding into the foramen.The rates of complaints for implant positioning and protrusion out of the vertebral body were determined to be acceptable.No devices were returned for evaluation.This submission is for 1 of 4 devices involved in this event.
 
Event or Problem Description
A stalif m flx cage was implanted in the patient on (b)(6) 2021 along with 3 stalif midline abo screws.The cage was implanted off of midline and one of the lateral screws was found to be protruding into the foramen about 1mm.This is believed to have caused the patient radiculopathy and leg pain.The surgeon determined that the cage and screws should be revised to correct the positioning.The revision procedure was performed on (b)(6) 2021.The access to the treated level took approximately 1 hour due to scar tissue formation.Once the level was exposed, the surgeon removed the 1st of 3 screws without any issues.The 2nd screw was removed with some bleeding that was controlled.The patient's iliac vein was across the 3rd screw.The vein had scar tissue adherence and was bleeding.The surgeons attempted to control the bleeding and mobilize the vein to remove the 3rd screw; however, the bleeding became uncontrollable.For approximately 3.5 hours the surgeons tried to control the bleeding from the vein, but the patient expired on the operating table due to blood loss.The patient died on (b)(6) 2021.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
STALIF MIDLINE ABO SCREW 6 X 35MM
Common Device Name
INTERVERTEBRAL FUSION DEVICE WITH INTEGRATED FIXATION, LUMBAR
Manufacturer (Section D)
CENTINEL SPINE, LLC.
900 airport rd, suite 3b
west chester PA 19380
MDR Report Key12337985
Report Number3007494564-2021-00069
Device Sequence Number5087618
Product Code OVD
UDI-Device Identifier00815101029313
UDI-Public00815101029313
Combination Product (Y/N)N
Initial Reporter StateTX
Initial Reporter CountryUS
PMA/510(K) Number
K173347
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2021
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source distributor
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial
Report Date (Section B) 08/10/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date11/20/2023
Device Model NumberSTM6035
Device Catalogue NumberN/A
Device Lot Number2020-0562
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 07/27/2021
Initial Report FDA Received Date08/18/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Death; Required Intervention;
Patient Age46 YR
-
-