PENUMBRA, INC. PENUMBRA SYSTEM JET7 REPERFUSION CATHETER; NRY Back to Search Results
Model Number 5MAXJET7BKIT-A
Medical Device Problem Codes Break (1069); Physical Resistance/Sticking (4012)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 07/25/2021
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The device has been returned and the investigation results are pending.A follow up mdr will be submitted upon completion of the device investigation.
 
Event or Problem Description
The patient was undergoing a thrombectomy procedure in the middle cerebral artery (mca) using a penumbra system jet 7 reperfusion catheter (jet7), a velocity delivery microcatheter (velocity), and a guidewire.During the procedure, the physician made the first pass with the adapt technique using a jet7 and a velocity.While retracting the jet7 with clot, the physician experienced resistance and broke the jet7 into two pieces at the mid-shaft.Therefore, the physician removed the jet7 by pulling it out of the patient¿s body.The procedure was completed using a stent retriever and the same velocity.There was no report of an adverse effect to the patient.
 
Additional Manufacturer Narrative
Evaluation of the returned jet7 revealed stretching and a fracture on the distal shaft.If the device is forcefully retracted against resistance, damage such as this may occur.The root cause of resistance during the procedure could not be determined.Further evaluation revealed bends along the catheter.This damage was likely incidental to the reported complaint.Penumbra catheters are inspected during in-process inspection and during quality inspection after manufacturing.The manufacturing records for this lot were reviewed and did not reveal any outstanding discrepancies, design, or quality concerns.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PENUMBRA SYSTEM JET7 REPERFUSION CATHETER
Common Device Name
NRY
Manufacturer (Section D)
PENUMBRA, INC.
one penumbra place
alameda CA 94502
MDR Report Key12339768
Report Number3005168196-2021-01829
Device Sequence Number4980814
Product Code NRY
UDI-Device Identifier00815948023246
UDI-Public00815948023246
Combination Product (Y/N)Y
Initial Reporter StateFL
Initial Reporter CountryUS
PMA/510(K) Number
K173761
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 09/10/2021
Report Date (Section F) 01/01/2005
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date01/08/2024
Device Model Number5MAXJET7BKIT-A
Device Catalogue Number5MAXJET7BKIT
Device Lot NumberF103182
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer08/11/2021
Was the Report Sent to FDA? Yes
Date Report to Manufacturer01/10/2005
Initial Date Received by Manufacturer 07/25/2021
Supplement Date Received by Manufacturer08/25/2021
Initial Report FDA Received Date08/18/2021
Supplement Report FDA Received Date09/10/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient Age74 YR
Date Report Sent to FDA01/01/2005
-
-