| Model Number |
IPN040140 |
| Medical Device Problem Code |
No Flow (2991)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
08/19/2021
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Qn#: (b)(4).The device has not been returned for investigation.Teleflex will continue to monitor and trend related events.
|
| |
|
Event or Problem Description
|
|
The tube was blocked when doing clinical setting before using on the same patient in the same operation.Involved 2 pcs.
|
| |
|
Additional Manufacturer Narrative
|
|
(b)(4).The customer reported the catheter was blocked.The customer returned one opened kit.The snaplock assembly and epidural catheter were removed from the returned kit and were visually examined with and without magnification.Visual examination of the returned snaplock assembly revealed the snaplock appears typical with no observed defects or anomalies.Visual examination of the catheter revealed the catheter was returned still sealed in its plastic pouch.The returned catheter was removed from the sealed pouch.The returned catheter appears typical with no defects or anomalies were observed.A functional flow test was performed on the returned sample per amrq-000017 section 7.8; rev.9.The returned epidural catheter was inserted from the proximal end into the returned snaplock assembly until it bottomed out and the snaplock assembly was closed.The components were confirmed to be secured by tugging gently.The snaplock assembly was connected to the lab leak tester (ref-002902) and the pressure was increased to 10 psi to establish flow.Water could be seen immediately exiting the distal end of the catheter.The flow rate was measured at 9.0ml/min (stopwatch: ref-003150), which is within the specification of 1ml/min minimum.No blockages were found.A corrective action is not required at this time as there were no functional issues found with the returned sample.The reported complaint of the catheter being blocked could not be confirmed based on the sample received.A device history record review was performed on the epidural catheter with no evidence to suggest a manufacturing related issue.The returned components passed a functional flow test and met flow rate specifications.There were no functional issues found with the returned sample.
|
| |
|
Event or Problem Description
|
|
The tube was blocked when doing clinical setting before using on the same patient in the same operation.Involved 2 pcs.
|
| |
|
Event or Problem Description
|
|
The tube was blocked when doing clinical setting before using on the same patient in the same operation.Involved 2 pcs.
|
| |
|
Additional Manufacturer Narrative
|
|
(b)(4), a device history record review was performed on the epidural catheter with no relevant findings.A corrective action is not required at this time as a potential root cause could not be determined based upon the information provided and without a sample.Complaint verification testing could not be performed as no sample was returned for analysis.A device history record review was performed on the epidural catheter with no evidence to indicate a manufacturing related issue.Therefore, the potential cause of this complaint could not be determined based upon the information provided and without a sample.No further action is required at this time.
|
| |
|
Search Alerts/Recalls
|