| Catalog Number |
06P04-60 |
| Medical Device Problem Code |
False Positive Result (1227)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
01/01/2021
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
There was no further information provided by the customer for donors.An evaluation is in process.A follow-up report will be submitted when the evaluation is complete.
|
| |
|
Event or Problem Description
|
|
The customer observed (b)(6) alinity s anti-hcv results on multiple donor specimens which confirmed negative by confirmatory testing.The results provided were: (b)(6).The alinity s processing module not in test of record before (b)(6) 2021.Those data provided (b)(6) 2020 through (b)(6) 2020 for validation on alinity s processing module.There was no reported impact to patient management.
|
| |
|
Additional Manufacturer Narrative
|
|
This submission being send for additional information provided on 25aug2021; section d10: new concomitant product: was updated to include alnty s processing modu, 06p16-01; serial number: (b)(6).
|
| |
|
Additional Manufacturer Narrative
|
|
The complaint evaluation included a review of data and information provided by the customer, search for similar complaints, ticket trending review, labeling review, device history record review, field data history of alinity s anti-hcv reagent, ln 6p04-60, lot number 22195be00.The ticket search determined that there is normal complaint activity for the likely cause lot.A review of tracking and trending did not identify any trends for the complaint issue.Return testing was not completed as returns were not available.Device history record review did not identify any non-conformances or deviations with the complaint lot and complaint issue.The customer data review for alinity s anti-hcv reagent, lot number 22195be00 was performed.The analysis included initial reactive rates (irr), repeat reactive rates (rrr) and specificity (assuming zero prevalence) at innovative blood resources (ibr), us whole blood (wb) peer sites and across all us customer sites and us whole blood (wb) peer sites.The specificity and reactive rate performance of lot 22195be00 at ibr is comparable to the performance at peer sites and within product requirements.Further, the overall irr, rrr and specificity of lots 22195be00 across all us customer sites are within product requirements and accordant to the performance of all lots of the same assay evaluated in the comparison (irr: 0.056 to 0.251%; rrr: 0.054 to 0.251%; specificity: 99.749 to 99.946%).A review of the manufacturing documentation did not identify any issues associated with the customer¿s observation.There was no issue with reagent performance identified.A review of the product labeling concluded that the issue is sufficiently addressed.Based on the investigation no product deficiency was identified for the alinity s anti-hcv reagent, lot number 22195be00.
|
| |
|
Additional Manufacturer Narrative
|
|
Section b5 was updated to remove the statement ¿the alinity s processing module not in test of record before (b)(6) 2021.Those data provided (b)(6) 2020 through (b)(6) 2020 for validation on alinity s processing module.¿ and add a clarification to indicate that the customer only provided a summary of results and did not provide any individual patient results.Section g1 contact information was updated to reflect the current contact (b)(6).
|
| |
|
Event or Problem Description
|
|
The customer observed false repeat reactive alinity s anti-hcv results on multiple donor specimens which confirmed negative by confirmatory testing.The customer provided the following summary of repeat reactive and confirmatory results across several months/reagent lots.No individual patient results were provided.(b)(6) 2021 repeat reactive=26 / confirmatory testing negative= 20; (b)(6) 2021 repeat reactive=34/ confirmatory testing negative = 30; (b)(6) 2021 repeat reactive=28 / confirmatory testing negative = 16; (b)(6) 2021 repeat reactive=27 / confirmatory testing negative = 17; (b)(6) 2021 repeat reactive=31 / confirmatory testing negative = 21; (b)(6) 2021 repeat reactive=24 / confirmatory testing negative = 17.There was no reported impact to patient management.
|
| |
|