PHILIPS MEDICAL SYSTEMS NEDERLAND B.V. BRILLIANCE; SYSTEM, X-RAY, TOMOGRAPHY, COMPUTED Back to Search Results
Model Number BRILLIANCE 64 UPGRADES
Medical Device Problem Code Crack (1135)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 08/20/2021
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
We have not completed our investigation of this event.We will file a follow-up emdr at the completion of the investigation.Internal cross reference: complaint (b)(4).
 
Event or Problem Description
The issue reported was that during a planned maintenance (pm) visit it was discovered that one of the welds on the heat exchanger had a crack in the seam.Based on the information available at this time, this event has been determined to be reportable.
 
Additional Manufacturer Narrative
The issue reported was that during a planned maintenance (pm) visit, it was discovered that one of the welds on the heat exchanger had a crack in the seam.A philips field service engineer (fse) confirmed the heat exchanger was not loose in anyway.The system was not in clinical use when this occurred.The fse replaced the cooling unit at the site and returned the system to the customer for clinical use.The faulty heat exchanger was returned for investigation.The analysis from the faulty heat exchanger concluded: the cracked weld seam is one of 12 (6 on each side) weld seams, the design is symmetric.The welds connect the heat exchanger to the gantry mounting plate (bracket).The mounting plate is mounted with 4 screw connections on each side to the ct gantry when the cooling unit is installed.The crack found was located at the inlet side of the heat exchanger.A mechanical stability simulation was done and the result was that even with 4 broken welds the safety factor was still sufficient.Conclusion: there is not a hazard situation of detached component (tube heat exchanger) expelled for this case.An analysis was also performed by the supplier which concluded the following: the most plausible root cause is temperature cycling fatigue damage related to the manufacturing date of cooling unit of more than 10 years old (whilst the lifetime is 10 years).The probable cause was temperature cycling fatigue damage on cooling units on average more than 10 years old.Therefore, based on the investigation performed, this event is considered a non-reportable event.The system did not cause or contribute to a death or serious injury, or serious deterioration and would not cause a death or serious injury, or serious deterioration if this event were to recur.Internal cross reference: complaint pr# (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BRILLIANCE
Common Device Name
SYSTEM, X-RAY, TOMOGRAPHY, COMPUTED
Manufacturer (Section D)
PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
veenpluis 4-6
best 5684 PC
NL  5684 PC
Manufacturer (Section G)
PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
veenpluis 4-6
best 5684 PC
NL   5684 PC
Manufacturer Contact
beth johnson
100 park avenue, suite 300
orange village, OH 44122
MDR Report Key12418847
Report Number3015777306-2021-10010
Device Sequence Number19881694
Product Code JAK
UDI-Device Identifier00884838083325
UDI-Public00884838083325
Combination Product (Y/N)N
Initial Reporter CountryGM
PMA/510(K) Number
K033326
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,User Facility,Company Representative
Initial Reporter Occupation Biomedical Engineer
Type of Report Initial,Followup
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Model NumberBRILLIANCE 64 UPGRADES
Device Catalogue Number728231
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Distributor Facility Aware Date08/20/2021
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer 08/20/2021
Supplement Date Received by Manufacturer08/20/2021
Initial Report FDA Received Date09/02/2021
Supplement Report FDA Received Date12/10/2021
Was Device Evaluated by Manufacturer? (Y/N) Yes
Is the Device Labeled for Single Use? (Y/N) No
Usage of Device Reuse
Patient Sequence Number1
Patient SexUnknown
-
-