Model Number M635TU70040
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Thrombosis/Thrombus (4440)
Date of Event 08/16/2021
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that thrombosis occurred.A left atrial appendage (laa) closure procedure was being performed.A watchman truseal access system (was) was positioned and a 24mm watchman flx laa closure device & delivery system (wds) were used.Thrombus was noted on the was after the device was deployed.The device met release criteria.The activated clotting time (act) was 120 seconds despite 10,000 units being given which was appropriate dosing for the patient's weight.The physician aspirated the thrombus and it was identified and flushed out of the sheath at the end of the case.No complications were noted in relation to this event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
WATCHMAN TRUSEAL ACCESS SYSTEM
Common Device Name
SYSTEM, APPENDAGE CLOSURE, LEFT ATRIAL
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
MDR Report Key12423330
Report Number2134265-2021-11125
Device Sequence Number19688229
Product Code DQY
UDI-Device Identifier08714729965725
UDI-Public08714729965725
Combination Product (Y/N)N
Initial Reporter StateTX
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 09/03/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date04/21/2024
Device Model NumberM635TU70040
Device Catalogue NumberM635TU70040
Device Lot Number0027186979
Was Device Available for Evaluation? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 08/16/2021
Initial Report FDA Received Date09/03/2021
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age77 YR
Patient Weight60
-
-