STRYKER ORTHOPAEDICS-MAHWAH TRIATHLON CR FEM COMP #5 L-CEM; PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, CO Back to Search Results
Model Number 5510-F-501
Medical Device Problem Codes Inadequacy of Device Shape and/or Size (1583); Loss of Osseointegration (2408); Unintended Movement (3026)
Health Effect - Clinical Codes Pain (1994); Osteolysis (2377); Inadequate Osseointegration (2646); Swelling/ Edema (4577)
Date of Event 01/18/2011
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
An event regarding osteolysis, migration and incorrect selection involving a triathlon femoral component was reported.The event was confirmed via clinician review.Method & results: device evaluation and results: could not be performed as the subject device was not returned.Medical records received and evaluation: a review of the provided medical records by a clinical consultant indicated: patient underwent primary right total knee arthroplasty in 2009 that failed in 2011, with lysis of adhesions and poly exchange.That revision surgery failed again due to loosening and the patient had another revision in 2013.That surgery also failed due to loosening.I can confirm that the events occurred since i was able to review the operation reports, office notes and i reviewed pre op and post op x-rays.Regarding the possible root cause of this event, i cannot determine this for certain.I don¿t see any abnormality with the implants.Loosening is a well-known complication.Operative technique, soft tissue balancing and cementing technique are key in the longevity of a total knee replacement.Failures in revision and re-revision surgery can also be attributed to surgical technique and prosthetic selection (augments, gap balancing, restoration of joint line, etc.Device history review indicated the devices accepted into final stock from the reported lot were free from discrepancies.Complaint history review: there has been no other event for the lot referenced.Conclusions: it was reported that at surgery they found that the femoral component was slightly elevated anteriorly and may have resulted in narrowing the patellofemoral space.They removed the femoral component and there was some bone loss laterally and anteriorly and posteriorly.They found on the medial side the posterior condyle had not been fully resected and they downsized to a size 4.The event was confirmed via clinician review.The exact cause of the event could not be determined.If further information becomes available or the product is returned, this investigation will be re-opened.Not returned.
 
Event or Problem Description
It was reported that; after revision surgery, patient states that he continues to experience pain and swelling on left knee.Patient has had bone scans and is currently following up with surgeon as he states his knee feels loose.*update on 16-aug-2021: this pi is for the second revision on (b)(6) 2013.Per medical review, "the patient underwent a second revision on (b)(6) 2013 with a diagnosis of a painful unstable left total knee arthroplasty.At surgery they found that the femoral component was slightly elevated anteriorly and may have resulted in narrowing the patellofemoral space.They removed the femoral component there was some bone loss laterally and anteriorly and posteriorly, they found on the medial side the posterior condyle had not been fully resected and they downsized to a size 4.The tibial component was also loose.The patella had a scratch on it and they removed it.They then cemented a triathlon size 4 universal base plate and cemented a triathlon x3 symmetrical 9 mm thick patella.They used a size 4 ¿ 16mm total stabilized poly insert.".
 
Additional Manufacturer Narrative
Corrected data: date of implant.
 
Event or Problem Description
It was reported that; after revision surgery, patient states that he continues to experience pain and swelling on left knee.Patient has had bone scans and is currently following up with surgeon as he states his knee feels loose.Update on 16-aug-2021: this pi is for the second revision on (b)(6) 2013.Per medical review, "the patient underwent a second revision on (b)(6) 2013 with a diagnosis of a painful unstable left total knee arthroplasty.At surgery they found that the femoral component was slightly elevated anteriorly and may have resulted in narrowing the patellofemoral space.They removed the femoral component there was some bone loss laterally and anteriorly and posteriorly, they found on the medial side the posterior condyle had not been fully resected and they downsized to a size 4.The tibial component was also loose.The patella had a scratch on it and they removed it.They then cemented a triathlon size 4 universal base plate and cemented a triathlon x3 symmetrical 9 mm thick patella.They used a size 4 ¿ 16mm total stabilized poly insert.".
 
Event or Problem Description
It was reported that; after revision surgery, patient states that he continues to experience pain and swelling on left knee.Patient has had bone scans and is currently following up with surgeon as he states his knee feels loose.*update on 16-aug-2021: this pi is for the second revision on (b)(6) 2013.Per medical review, "the patient underwent a second revision on (b)(6), 2013 with a diagnosis of a painful unstable left total knee arthroplasty.[.] at surgery they found that the femoral component was slightly elevated anteriorly and may have resulted in narrowing the patellofemoral space.They removed the femoral component there was some bone loss laterally and anteriorly and posteriorly, they found on the medial side the posterior condyle had not been fully resected and they downsized to a size 4.The tibial component was also loose.The patella had a scratch on it and they removed it.[.] they then cemented a triathlon size 4 universal base plate and cemented a triathlon x3 symmetrical 9 mm thick patella.They used a size 4 ¿ 16mm total stabilized poly insert.".
 
Additional Manufacturer Narrative
Reported event: an event regarding loosening involving a triathlon femoral component was reported.The event was confirmed via clinician review.Method & results: -device evaluation and results: could not be performed as the subject device was not returned.-medical records received and evaluation: a review of the provided medical records by a clinical consultant indicated: patient underwent primary right total knee arthroplasty in 2009 that failed in 2011, with lysis of adhesions and poly exchange.That revision surgery failed again due to loosening and the patient had another revision in 2013.That surgery also failed due to loosening.I can confirm that the events occurred since i was able to review the operation reports, office notes and i reviewed pre op and post op x-rays.Regarding the possible root cause of this event, i cannot determine this for certain.I don¿t see any abnormality with the implants.Loosening is a well-known complication.Operative technique, soft tissue balancing and cementing technique are key in the longevity of a total knee replacement.Failures in revision and re-revision surgery can also be attributed to surgical technique and prosthetic selection (augments, gap balancing, restoration of joint line, etc.-device history review indicated the devices accepted into final stock from the reported lot were free from discrepancies.-complaint history review: there has been no other event for the lot referenced.Conclusions: it was reported that at surgery they found that the femoral component was slightly elevated anteriorly and may have resulted in narrowing the patellofemoral space.They removed the femoral component and there was some bone loss laterally and anteriorly and posteriorly.They found on the medial side the posterior condyle had not been fully resected and they downsized to a size 4.The event was confirmed via clinician review.The exact cause of the event could not be determined.If further information becomes available or the product is returned, this investigation will be re-opened.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TRIATHLON CR FEM COMP #5 L-CEM
Common Device Name
PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, CO
Manufacturer (Section D)
STRYKER ORTHOPAEDICS-MAHWAH
325 corporate drive
mahwah NJ 07430
MDR Report Key12444878
Report Number0002249697-2021-01526
Device Sequence Number12012742
Product Code MBH
UDI-Device Identifier07613327040296
UDI-Public07613327040296
Combination Product (Y/N)N
Initial Reporter StateGA
Initial Reporter CountryUS
PMA/510(K) Number
K141056
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2011
Device Explanted Year2013
Reporter Type Manufacturer
Report Source consumer,other
Initial Reporter Occupation Other
Type of Report Initial,Followup,Followup
Report Date (Section B) 10/14/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date07/31/2014
Device Model Number5510-F-501
Device Catalogue Number5510F501
Device Lot NumberSNJ7K
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 08/16/2021
Supplement Date Received by Manufacturer08/17/2021
09/17/2021
Initial Report FDA Received Date09/09/2021
Supplement Report FDA Received Date09/13/2021
10/14/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Hospitalization; Required Intervention;
Patient Age54 YR
Patient Weight100
-
-