BD MEDICAL (BD WEST) MEDICAL SURGICAL NEEDLE 26X1/2 RB; HYPODERMIC SINGLE LUMEN NEEDLE Back to Search Results
Catalog Number 305111
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Hyperglycemia (1905)
Date of Event 08/06/2021
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Medical device expiration date: unknown.Device manufacture date: unknown.Investigation summary: bd implemented a thorough investigation following our corrective preventative action protocol.This was opened for a trend in reports of ¿needle clogged / blocked¿, ¿aspirate / draw (cannot / difficult)¿, and ¿needle bent¿.All three of these issues have the same net effect: temporary interruption of flow of insulin into the reservoir.Based on the investigation, these issues appear to be related to the use case which involves drawing insulin from a vial into a syringe and then filling the reservoir of the insulin pump via a small port off the body in an iterative process, utilizing existing / ¿off the shelf¿ products rather than a product designed for this use.Bd products are designed to be single use, and because this is an "off the shelf" product, bd specifications do not take into account any requirements specific to the tandem use case.The investigation concludes the complaints are related to the use case and not due to a product nonconformance.
 
Event or Problem Description
It was reported that needle 26x1/2 rb had a fill resistance issue.This occurred on 2 occasions.The following information was provided by the initial reporter: it was reported fill resistance issue.Caller reported fill resistance issue.Number of occurrences - 2 times did the caller insert the needle into the cartridge and encounter fill resistance? - yes was the syringe/needle reused? - no was the cartridge reused/refilled? - no product with issue caller did not have information at time of the call needle lot # - unavailable customer's bg at time of event - 566mg/dl ; between 54-500 mg/dl (3.0-27.7 mmol/l), no further bg questions required.Does insulin come out of the existing needle? ¿ n/a, issue happened in the past.Customer had already changed needle [and/] syringe at time of call.Was caller able to fill the existing cartridge with the second needle? ¿ yes.Resolution ¿ caller successfully loaded existing cartridge with second needle.Cts to send goodwill order of cartridges to replace needle.Is product available for return to bd? ¿caller does not have the syringe/needle information.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
NEEDLE 26X1/2 RB
Common Device Name
HYPODERMIC SINGLE LUMEN NEEDLE
Manufacturer (Section D)
BD MEDICAL (BD WEST) MEDICAL SURGICAL
1852 10th avenue
columbus NE 68601
MDR Report Key12464490
Report Number1911916-2021-00980
Device Sequence Number14469932
Product Code FMI
UDI-Device Identifier00382903051113
UDI-Public00382903051113
Combination Product (Y/N)N
Initial Reporter StateID
Initial Reporter CountryUS
PMA/510(K) Number
K021475
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source distributor,other
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 09/09/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Other
Device Catalogue Number305111
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 08/16/2021
Initial Report FDA Received Date09/13/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient Age67 YR
-
-