| Model Number |
FDS40020 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Headache (1880); Stenosis (2263)
|
| Date of Event |
06/02/2021
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Device is implanted in patient.
|
| |
|
Event or Problem Description
|
|
It was reported that during a clinical trial procedure for a left ophthalmic saccular aneurysm in the internal carotid artery, the subject flow diverter was implanted successfully.Pre procedure imaging did not indicate any additional abnormalities.Procedure angiogram indicated 0-25% stenosis in the parent artery and in the subject flow diverter implanted which had no clinical significance to the patient.One day post procedure, the patient experienced non serious persistent ipsilateral headaches that were unrelieved by tylenol.Patient medication was changed to fioricet and the headaches resolved.No other information is available.
|
| |
|
Event or Problem Description
|
|
It was reported that during a clinical trial procedure for a left ophthalmic saccular aneurysm in the internal carotid artery, the subject flow diverter was implanted successfully.Pre procedure imaging did not indicate any additional abnormalities.Procedure angiogram indicated 0-25% stenosis in the parent artery and in the subject flow diverter implanted which had no clinical significance to the patient.One day post procedure, the patient experienced non serious persistent ipsilateral headaches that were unrelieved by tylenol.Patient medication was changed to fioricet and the headaches resolved.No other information is available.
|
| |
|
Additional Manufacturer Narrative
|
|
Based on the results of the dhr review, there is no indication that the device, labeling or packaging failed to meet its specifications when released.The reported complaint not be confirmed, and it could not be definitively determined if the device failed to meet specifications because the product was not returned.The reported event is covered in the device directions for use (dfu).As well, the risk of the reported event is documented in the risk documentation and there are current controls to mitigate the risk of the as reported event.Per the ae description ¿persistent left sided headaches unrelieved by tylenol no visual changes started fioricet¿.This is classified as a worsening focal ipsilateral headache by the site but not a suspected stoke event.Medication was given for the event, no other medical intervention is indicated in edc.Procedure angiogram indicates 0-25% stenosis (which is equivalent to no clinically significant stenosis).The reported 'patient parent vessel stenosis' and 'patient headache non-serious', are known and anticipated complications to these types of procedures and patient condition and is listed as such in the device directions for use.Therefore, a probable cause of anticipated procedural complication was assigned to this event.
|
| |
|