Model Number RBYLP0204
Medical Device Problem Code Failure to Advance (2524)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 08/22/2021
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
This device is available for return.A follow up mdr will be submitted upon completion of the device investigation.This report is associated with mfr report number: 3005168196-2021-02086.
 
Event or Problem Description
The patient was undergoing a coil embolization procedure using ruby coil lps.During the procedure, two ruby coil lps would not advance out of the introducer sheaths.Therefore, they were removed.No additional information regarding the completion of the procedure was provided.There was no report of an adverse effect to the patient.
 
Additional Manufacturer Narrative
Evaluation of the returned ruby coil lp revealed that the pusher assembly mid-joint was retracted proximal to the introducer sheath friction lock.If this occurs, resistance will likely be experienced during advancement and the device may not advance out of the introducer sheath.During functional testing, the pusher assembly mid-joint was advanced through the introducer sheath friction lock with resistance, then additional resistance was experienced at the distal tip of the introducer sheath due to the unknown material inside the introduce sheath and the ruby coil lp was unable to advance through the introducer sheath.The unknown material inside the introducer sheath was likely incidental to the complaint.Further evaluation of the device revealed pusher assembly kink.This damage was likely incidental to the complaint and may have occurred during packaging for the device return.Penumbra coils are visually inspected during in-process inspection and during quality inspection after manufacturing.The manufacturing records for this lot were reviewed and did not reveal any outstanding discrepancies, design, or quality concerns.This report is associated with mfr report number: 3005168196-2021-02086 h3 other text : placeholder.
 
Additional Manufacturer Narrative
Please note that the following section was incorrectly reported on the initial mfr report and is being corrected on this follow-up #01 mfr report.1.Section b.Box 5.Describe event or problem this report is associated with mfr report number: 3005168196-2021-02086 h3 other text : placeholder.
 
Event or Problem Description
The patient was undergoing a coil embolization procedure using ruby coil lps.During the procedure, two ruby coil lps would not advance out of the introducer sheaths.Therefore, they were removed.The procedure was completed using a new lp coil.There was no report of an adverse effect to the patient.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
RUBY COIL LP
Common Device Name
HCG, KRD
Manufacturer (Section D)
PENUMBRA, INC.
one penumbra place
alameda CA 94502
Manufacturer Contact
veronica farris
one penumbra place
alameda, CA 94502
5107483200
MDR Report Key12496227
Report Number3005168196-2021-02087
Device Sequence Number16957787
Product Code HCG
UDI-Device Identifier00815948021754
UDI-Public00815948021754
Combination Product (Y/N)Y
Initial Reporter StateAL
Initial Reporter CountryUS
PMA/510(K) Number
K192955
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup,Followup
Report Date (Section B) 07/29/2022
Report Date (Section F) 01/01/2005
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date05/16/2026
Device Model NumberRBYLP0204
Device Catalogue NumberRBYLP0204
Device Lot NumberF106276
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/13/2021
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? Yes
Date Report to Manufacturer01/10/2005
Initial Date Received by Manufacturer 08/23/2021
Supplement Date Received by Manufacturer10/19/2021
01/14/2005
Initial Report FDA Received Date09/20/2021
Supplement Report FDA Received Date10/29/2021
07/30/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured05/17/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient Age75 YR
Patient SexUnknown
Patient Weight77 KG
Date Report Sent to FDA01/01/2005
-
-