Model Number P10.7-80B305
Medical Device Problem Code Mechanical Problem (1384)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 08/26/2021
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The device has not been returned for evaluation.The root cause is unable to be determined at this time.If any additional information is provided, a supplemental report will be submitted.
 
Event or Problem Description
Information was received that the patient's nail appeared to not be lengthening.A revision procedure was performed in order to create a new osteotomy.The nail still would not lengthen so it was swapped out.The swapped nail was able to lengthen and the patient is doing well.
 
Additional Manufacturer Narrative
Device evaluation: visual inspection of the returned product showed scratches and dents, and the nail was revealed to be fully retracted.X-ray images of internal components revealed a damaged anti-jam washer.X-ray images on the released work order were also verified and showed no signs of anti-jam washer failure.The length of the nail as received was measured at 302.90 mm.The nail was functionally tested and was unable to distract or retract with the electronic remote controller (erc) and high-speed magnet.As a part of the investigation, the device history records were reviewed and indicated the length of the nail was 303.90 mm at time of manufacture.The difference between the measurement of the nail at time of manufacture and return for complaint was 1mm.The shorter length measured at the time of the complaint investigation indicate that the nail had been retracted.The nail was determined to be jammed due to repeated retraction force from improper use of the erc.The erc unit may have been held in the incorrect orientation during the lengthening sessions causing the device to be retracted instead of being distracted.Device records review: a review of the dhr documents indicated that the nail was manufactured by the specified requirements at that time and met all of the required quality inspections before shipment.
 
Event or Problem Description
No additional information was provided.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PRECICE SYSTEM
Common Device Name
ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES
Manufacturer (Section D)
NUVASIVE SPECIALIZED ORTHOPEDICS, INCORPORATED
101 enterprise #100
aliso viejo CA 92656
Manufacturer (Section G)
NUVASIVE SPECIALIZED ORTHOPEDICS, INCORPORATED
101 enterprise #100
aliso viejo 92656
Manufacturer Contact
geoff gannon
101 enterprise #100
aliso viejo, CA 92656
8583448112
MDR Report Key12501931
Report Number3006179046-2021-00469
Device Sequence Number3695781
Product Code HSB
UDI-Device Identifier00812258020279
UDI-Public812258020279
Combination Product (Y/N)N
Initial Reporter StateFL
Initial Reporter CountryUS
PMA/510(K) Number
K173129
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2021
Device Explanted Year2021
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 11/12/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberP10.7-80B305
Device Lot Number1021809AAA
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/28/2021
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 08/26/2021
Supplement Date Received by Manufacturer11/10/2021
Initial Report FDA Received Date09/20/2021
Supplement Report FDA Received Date11/12/2021
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured02/18/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age40 YR
Patient SexFemale
Patient Weight61 KG
-
-