Model Number 1217-30-046
Medical Device Problem Code Osseointegration Problem (3003)
Health Effect - Clinical Codes Fall (1848); Inadequate Osseointegration (2646)
Date of Event 09/01/2021
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Product complaint # (b)(4).If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event or Problem Description
It was reported that the pt.Fell and fractured the proximal femur.It was also indicated that there was loosening of the stem and cup at the bone to implant interface.The stem was loose but during the case, they discovered that the cup was also loose.He revised both going to a 48 cup and corail revision stem.Everything was stable following the revision.Doi: (b)(6) 2021, dor: (b)(6)2021, affected side: left hip.
 
Additional Manufacturer Narrative
Product complaint # (b)(4).Investigation summary no device associated with this report was received for examination.The information received will be retained for potential series investigations if triggered by trend analysis, post market surveillance, or other events within the quality system.Depuy considers the investigation closed.Should additional information be received, the information will be reviewed, and the investigation will be re-opened as necessary.Device history lot the product investigation found no evidence suspecting an error in the material, manufacturing, inspection or sterile processing that would be a contributing factor in the reported allegation(s).A manufacturing records evaluation (mre) was not performed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PINN BANTAM W/GRIPTION 46MM
Common Device Name
PINNACLE HIP SYSTEM : HIP METAL ACETABULAR CUPS
Manufacturer (Section D)
DEPUY ORTHOPAEDICS INC US
700 orthopaedic drive
warsaw IN 46581 0988
MDR Report Key12512894
Report Number1818910-2021-20764
Device Sequence Number4032061
Product Code KWA
UDI-Device Identifier10603295009955
UDI-Public10603295009955
Combination Product (Y/N)N
Initial Reporter StateCO
Initial Reporter CountryUS
PMA/510(K) Number
K093646
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2021
Device Explanted Year2021
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 09/01/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number1217-30-046
Device Catalogue Number121730046
Device Lot NumberJA2113
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 09/01/2021
Supplement Date Received by Manufacturer10/12/2021
Initial Report FDA Received Date09/22/2021
Supplement Report FDA Received Date10/13/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
ALTRX NEUT 28IDX46OD; APEX HOLE ELIM POSITIVE STOP; DELTA CER HEAD 12/14 28MM +1.5; PINN BANTAM W/GRIPTION 46MM; SUMMIT DUOFIX TAP SZ2 STD OFF; ALTRX NEUT 28IDX46OD; APEX HOLE ELIM POSITIVE STOP; DELTA CER HEAD 12/14 28MM +1.5; PINN BANTAM W/GRIPTION 46MM; SUMMIT DUOFIX TAP SZ2 STD OFF
Outcome Attributed to Adverse Event Required Intervention;
Patient Age61 YR
-
-