• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BOSTON SCIENTIFIC CORPORATION WOLVERINE CORONARY CUTTING BALLOON; CATHETER, PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY (PTCA), CUTTING/SCORING

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC CORPORATION WOLVERINE CORONARY CUTTING BALLOON; CATHETER, PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY (PTCA), CUTTING/SCORING Back to Search Results
Model Number 3854
Medical Device Problem Codes Break (1069); Difficult to Remove (1528); Detachment of Device or Device Component (2907)
Health Effect - Clinical Code Foreign Body In Patient (2687)
Date of Event 09/02/2021
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that the balloon was stuck in the lesion and the tip broke off and remained inside the patient.The 95% stenosed target lesion was located in the severely tortuous and severely calcified mid coronary artery.A 10mmx4.00mm wolverine coronary cutting balloon was selected for use.During the procedure, the balloon was inflated up to 10 atmospheres and the blades were deployed in the lesion.The balloon was fully deflated and, upon removal, it was noted that the device was stuck in lesion.The physician attempted to retract the balloon with great force at which point the tip broke off.The device was not able to be retrieved after several attempts.The procedure was completed by stenting the device and left it inside the body.No patient complications were reported.
 
Additional Manufacturer Narrative
Corrected: h6 - device codes: initially reported (a0501)detachment of device or device component and corrected to (a0401)break.
 
Event or Problem Description
It was reported that the balloon was stuck in lesion, the tip broke off and was remained inside the patient.The 95% stenosed target lesion was located in the severely tortuous and severely calcified mid coronary artery.A 10mmx4.00mm wolverine coronary cutting balloon was selected for use.During the procedure, the balloon was inflated up to 10 atmospheres and the blades were deployed in the lesion.Upon removal, the balloon was fully deflated and it was noted that the device was stuck in lesion.The physician attempted to retract the balloon with great force at which point the tip broke off.The device was not able to be retrieved after several attempts.The procedure was completed by stenting the device and left it inside the body.No patient complications were reported.It was further reported that the distal portion of the device including balloon/blades broke off.The balloon was fully deflated before attempting to pull the device back into the guidecather.
 
Additional Manufacturer Narrative
Device evaluated by manufacturer: the device was returned for analysis and evaluation and the distal portion of the device included the balloon and blades was not returned for analysis.The shaft of the device was found to be separated at approx.24cm distal to the guidewire port.On the portion of the device that was returned, the following issues were noted: multiple hypotube kinks were present, mid shaft and the guidewire port region were found to be stretched.A blood like substance was visible inside the manifold region and along the inflation lumen.
 
Event or Problem Description
It was reported that the balloon was stuck in lesion, the tip broke off and was remained inside the patient.The 95% stenosed target lesion was located in the severely tortuous and severely calcified mid coronary artery.A 10mmx4.00mm wolverine coronary cutting balloon was selected for use.During the procedure, the balloon was inflated up to 10 atmospheres and the blades were deployed in the lesion.Upon removal, the balloon was fully deflated and it was noted that the device was stuck in lesion.The physician attempted to retract the balloon with great force at which point the tip broke off.The device was not able to be retrieved after several attempts.The procedure was completed by stenting the device and left it inside the body.No patient complications were reported.It was further reported that the distal portion of the device including balloon/blades broke off.The balloon was fully deflated before attempting to pull the device back into the guide catheter.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
WOLVERINE CORONARY CUTTING BALLOON
Common Device Name
CATHETER, PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY (PTCA), CUTTING/SCORING
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
MDR Report Key12522532
Report Number2134265-2021-11796
Device Sequence Number17198818
Product Code NWX
UDI-Device Identifier08714729888307
UDI-Public08714729888307
Combination Product (Y/N)N
Initial Reporter StateTN
Initial Reporter CountryUS
PMA/510(K) Number
P950020
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Physician
Type of Report Initial,Followup,Followup
Report Date (Section B) 10/20/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date08/21/2022
Device Model Number3854
Device Catalogue Number3854
Device Lot Number0025899291
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/20/2021
Initial Date Received by Manufacturer 09/02/2021
Supplement Date Received by Manufacturer09/27/2021
10/15/2021
Initial Report FDA Received Date09/23/2021
Supplement Report FDA Received Date10/13/2021
10/20/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
-
-