| Model Number |
1221-32-054 |
| Medical Device Problem Code |
Device Dislodged or Dislocated (2923)
|
| Health Effect - Clinical Codes |
Insufficient Information (4580); Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581)
|
| Date of Event |
09/10/2021
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
(b)(4).If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Event or Problem Description
|
|
Patient operated 2017 (b)(6) clinic.Reoperated due to liner disassociation.Doi: 2017, dor: unknown, unknown side.
|
| |
|
Additional Manufacturer Narrative
|
|
Product complaint # (b)(4).This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by depuy synthese joint reconstruction, or its employees that the report constitutes an admission that the product, depuy synthese joint reconstruction, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.
|
| |
|
Additional Manufacturer Narrative
|
|
Product complaint # (b)(4).This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by depuy synthes joint reconstruction, or its employees that the report constitutes an admission that the product, depuy synthes joint reconstruction, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.Corrected: b3 and h6 (patient).
|
| |
|
Event or Problem Description
|
|
A.Date of event: 2017 c.What is the affected side involved in this event? no information d.Was surgery time extended? if yes, what is the duration of the delay? no delay e.Was the cup available for return? yes f.For reports of disassociation we are required to enter the acetabular cup even if it was not revised.Can you please provide the acetabular cup product / lot information? yes, it has been involved in the first report due to the nature of the reported event, and in accordance with our procedures, we are required to request the following information to assist in the investigation.Please could you let me know if any/none of this information is available: - 1.Radiographs/x-ray films please provide all x-rays relevant to the reported event for example - pre-operative, post primary, pre-revision and intervening time points.Provided in first report 2.Patient demographics the following are the types of patient demographics we require: - - relevant comorbidities, date of implantation, date of revision, operative side, age at the time of the procedure, weight, height, and activity level.2017 3.Implant insertion op notes:- please provide all notes relevant to the reported event for example: - - reason for implant insertion, device labels, surgery report, physiotherapy report, early falls and/or dislocations.No info.4.Implant removal op notes:- please provide all notes relevant to the reported event for example: - - reason for revision, surgeon report and product and lot codes of devices remaining in situ.Liner disassociation, totally loose liner.
|
| |
|
Additional Manufacturer Narrative
|
|
Product complaint # (b)(4).This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by depuy synthes joint reconstruction, or its employees that the report constitutes an admission that the product, depuy synthes joint reconstruction, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.
|
| |
|
Additional Manufacturer Narrative
|
|
Product complaint # (b)(4).Investigation summary examination of the returned device and provided images found evidence to support disassociation of the liner from the cup while implanted.Depuy considers the investigation closed.Should additional info be received, the investigation will be re-opened as necessary.Device history lot a worldwide complaint database search found no additional related reports against the provided product code/lot number combination.Based on the inability to find any additional related reports against the provided product code/lot number combination, it is reasonable to conclude that there are no anomalies with regard to manufacturing or inspection contained in the device history records that would contribute to the reported event.H10 additional narrative:.
|
| |
|
Search Alerts/Recalls
|