Model Number N/A
Device Problem Fluid/Blood Leak (1250)
Patient Problem Hemorrhage/Bleeding (1888)
Event Date 09/08/2021
Event Type  malfunction  
Manufacturer Narrative
The device has not been returned to the manufacturer for evaluation.A lot history review (lhr) review is not possible, as no manufacturing lot number has been provided by the complainant.
 
Event Description
It was reported a break at the tubing of the port on a power port.The patient was not harmed, however there was a lot of blood backing up and leaked on the bed.We are monitoring for central line infection.
 
Manufacturer Narrative
H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant/reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.The following were reviewed as part of this investigation: patient severity, trend analysis, applicable previous investigation(s), sample (if available), and applicable fmea documents.Based on a review of this information, the following was concluded: the complaint of a damaged infusion set was confirmed.The product returned for evaluation was one 20ga x 1¿ powerloc max safety infusion set.Usage residues were observed throughout the sample.A needleless injection cap was attached to the luer adapter and the safety mechanism was engaged.A partially circumferential split was observed at the luer/tubing joint.Microscopic inspection of the split revealed a granular fracture surface.Beach marks and radiating tear marks were observed throughout the fracture surface.Material buckling and discoloration were observed in the vicinity of the split.The split characteristics and material buckling were consistent with material failure due to repetitive stress.It appeared that the tubing fractured, in part, due to repetitive torsional (twisting) stress; however, an additional unidentified factor(s) also have contributed.The supplier has been notified of this event.A lot history review (lhr) of asfpf085 showed no other similar product complaint(s) from this lot number.H3 other text: evaluation findings are in section h11.
 
Event Description
It was reported a break at the tubing of the port on a power port.The patient was not harmed, however there was a lot of blood backing up and leaked on the bed.We are monitoring for central line infection.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
POWERLOC MAX POWER-INJECTIBLE INFUSION SET 20G X 1.0 IN
Type of Device
SET, ADMINISTRATION, INTRAVASCULAR
Manufacturer (Section D)
C.R. BARD, INC. (BASD) -3006260740
605 north 5600 west
salt lake city 84116
Manufacturer (Section G)
C.R. BARD, INC. (BASD) -3006260740
605 north 5600 west
salt lake city 84116
Manufacturer Contact
johanna de oliveira
605 north 5600 west
salt lake city 84116
8015950700
MDR Report Key12542531
MDR Text Key273675090
Report Number3006260740-2021-04029
Device Sequence Number1
Product Code FPA
UDI-Device Identifier00801741047442
UDI-Public(01)00801741047442
Combination Product (y/n)N
Reporter Country CodeCA
PMA/PMN Number
K153440
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other,Company Representative
Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date 12/17/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberN/A
Device Catalogue Number0142010
Device Lot NumberASFPF085
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer11/22/2021
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 09/08/2021
Initial Date FDA Received09/28/2021
Supplement Dates Manufacturer Received12/16/2021
Supplement Dates FDA Received12/21/2021
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured02/01/2021
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Other;
-
-