| Model Number |
1219-36-154 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Pain (1994); Joint Laxity (4526); Unspecified Tissue Injury (4559); Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581)
|
| Date of Event |
09/16/2021
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Product complaint # (b)(4).If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Event or Problem Description
|
|
Patient underwent primary thr on (b)(6) 2018 where a corail pinnacle was utilised (dr (b)(6), (b)(6) hospital).Patient has reported that he was unhappy with the hip from the outset.Patient has presented with a painful hip (around the groin, greater troch and buttock - patient has a number of other conditions as well as spinal fusion so some of the pain could be due to his back), patient also has a clunking feeling in certain positions.On reviewing the x rays, the femoral stem appears to be in a reasonable position without any signs of loosening (although it may be a little undersized).The acetabular component appears to be too medial and too superior (indicating that the acetabulum may have been over reamed at time of index surgery, it appears that this may have reduced the overall lateral offset.On opening the hip (dr.(b)(6), (b)(6) hospital, (b)(6) 2021) the hip was moved through a rom and it appeared to be impinging on both soft tissue and bone.A decision was made to remove the pinnacle shell (which was a well fixed 54mm shell) and replace this with a larger acetabular component which would allow the cup to be placed more lateral.Bone graft was placed on the medial wall/ side.A 64mm competitor cup was placed, which resulted in an increase of lateral offset and the reduction of impingement on the pelvis and surrounding soft tissue.A dual mobility construct was utilised.The hip appeared stable without the impingement initially found.Doi: (b)(6) 2018.Dor: (b)(6) 2021.Unknown side.
|
| |
|
Event or Problem Description
|
|
Additional information received indicated that there was a surgical error and the cup was placed too medially with loss of offset.There was no loosening.Affected side was the left hip based on the images.
|
| |
|
Additional Manufacturer Narrative
|
|
Product complaint # (b)(4).This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by depuy synthes joint reconstruction, or its employees that the report constitutes an admission that the product, depuy synthes joint reconstruction, or its employees caused or contributed to the potential event described in this report.Appropriate term / code not available (e2402) is used to capture unspecified musculoskeletal problem - joint injury (e1635).If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.
|
| |
|
Additional Manufacturer Narrative
|
|
Product complaint # (b)(4).Investigation summary : no device associated with this report was received for examination.A worldwide complaint database search found no other related reported incidents against the provided product code/lot number combination since release for distribution.Based on previous investigations, this complication of joint replacement is unlikely to have been the result of a device failing to meet required specifications.The information received will be retained for potential series investigations if triggered by trend analysis, post market surveillance, or other events within the quality system.Device history lot : a worldwide complaint database search found no additional related reports against the provided product code/lot number combination.Based on the inability to find any additional related reports against the provided product code/lot number combination, it is reasonable to conclude that there are no anomalies with regard to manufacturing or inspection contained in the device history records that would contribute to the reported event.
|
| |
|